Stock · 1 unit

When you turn on the hot water tap or activate the heating, the Siemens PCB for Combi 28 HE, Duo Tec, and Platinum Combi is responsible for controlling the ignition, burner modulation, and the boiler pump. If this part fails, you may notice that the boiler does not start, gets locked, or exhibits erratic operation, which can generate fault codes such as E151, E154, or E135. This board is compatible with models from the Combi, Duo, and Platinum ranges, including the Combi 28 HE and the Duo Tec 28 HE. It should be replaced when you experience operational issues or errors are displayed in the system.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 7690360

PCB with reference 7690360. 12 verified compatibilities: 28 HE and Tec 24 HE.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca 28 HECombiContrasted
Baxi Roca Tec 24 HEDuoContrasted
Baxi Roca Tec 28 HEDuoContrasted
Baxi Roca Tec 28 HE ADuoContrasted
Baxi Roca Tec 33 HEDuoContrasted
Baxi Roca Combi 24 HEPlatinumContrasted
Baxi Roca Combi 28 HEPlatinumContrasted
Baxi Roca Combi 28 HE APlatinumContrasted
Baxi Roca Combi 33 HEPlatinumContrasted
Baxi Roca Combi 40 HEPlatinumContrasted
Baxi Roca Gold Combi 28 HEPottertonContrasted
Baxi Roca Promax 28 HE PlusPottertonContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 7690360 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7690360. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 7690360 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler won't start, and a fault code for the PCB or communication appears on the display.

    Cause: The PCB manages all the logic of the boiler; an internal fault can cause that type of generic fault code.

    Cut the power for 30 seconds and then restore it to see if the fault code reappears before ruling out the PCB.

  • 02

    The burner ignites with an unstable flame, which rises and falls without apparent reason.

    Cause: The PCB modulates the gas valve according to demand; if its control electronics fail, the modulation becomes uncontrolled.

    Check the inlet gas pressure and the condition of the burner before attributing it to the PCB.

  • 03

    The thermostat in the house is not able to turn on the boiler even though it is requesting heat.

    Cause: The PCB receives that signal through its low voltage terminals and translates it into an ignition order.

    Bypass the demand directly on the PCB to rule out that the fault is in the thermostat or its wiring.

  • 04

    The boiler turns off by itself in the middle of a heating or domestic hot water cycle.

    Cause: An intermittent fault in the PCB can generate incorrect readings that cause a safety shutdown.

    Note the exact moment it turns off (start, modulation, stop) to determine whether the fault is with the PCB or a sensor.

Fault codes for Baxi Roca that this part resolves.

CodeFaultDiagnosis and solution
E151Internal error of the boiler's PCB.Internal fault of the PCB. Check voltages/grounds and connectors; if the error persists after reset and checks, confirm by replacing the PCB.
E154Internal boiler PCB error.Internal fault of the PCB. After reset and wiring inspection, if it reappears, check the power supply and replace the PCB.
E135Internal fault of the card.Internal fault of the PCB. Check power supply and perform a reset; if it does not resolve and there are no other causes, replace the board.
E.02 .16Timeout communication with the internal memory of the boiler's control board.The PCB cannot communicate with its internal memory (board fault). Check for electromagnetic disturbances and connections; if the issue persists, replace the main board.
E.02 .17Permanent communication failure between the gas valve and the boiler PCB.Communication fault of the PCB (bus/control) with the gas valve due to a fault in the board or line. Check harness/connectors CN1/CN2 and EMI; if not resolved, replace the board.
H.01 .00Temporary communication failure between the gas valve and the boiler PCB.Temporary communication interruption managed by the PCB; when the board fails, the warning reappears. Check CN1/CN2 and supply; if it persists, replace the main board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi Roca 7690360 PCB.

Catalogue reference
7690360
Brand
Baxi Roca
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
Siemens
Frequently Asked Questions

Frequently asked questions about the PCB 7690360

Who manufactures the PCB for the Combi 28 HE boiler?
The PCB is manufactured by Siemens, as indicated by the silkscreen logo on the board.
Does this PCB work for my Combi 28 HE boiler?
Yes, the Siemens PLBA148 PCB is compatible with the Combi 28 HE boiler, among other models.
Is the Siemens PLBA148 PCB compatible with the Duo Tec range?
Yes, it is compatible with the models Tec 24 HE, Tec 28 HE, Tec 28 HE A, and Tec 33 HE.
Does this PCB also work for the Potterton Promax 28 HE Plus?
Yes, the Potterton Promax 28 HE Plus is on the list of boilers compatible with the Siemens PLBA148 PCB.
What fault codes are compatible with this PCB?
The documented fault codes for this PCB are: E151, E154, E135, E.02 .16, E.02 .17, H.01 .00.
How many models are compatible with the Siemens PLBA148 PCB?
The PCB is compatible with a total of 12 boiler models.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model