Beretta Mynute thermohydrometer Ref. R10030294 · Ø42, 0–120 °C / 0–4 bar
Spherical thermohygrometer with dual needle, for simultaneous reading of temperature (0-120 °C) and pressure (0-4 bar) in the boiler circuit. The dial does not have the manufacturer's name printed nor any code other than the reference R10030294. It is replaced when it no longer measures accurately or the display is broken.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10030294
Pressure gauge with reference R10030294. Eight confirmed compatibilities: 18 CSI AR and 24 CAI AR.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta 18 CSI AR | Beretta Mynute | Contrasted |
| Beretta 24 CAI AR | Beretta Mynute | Contrasted |
| Beretta 24 CAI N | Beretta Mynute | Contrasted |
| Beretta 24 CSI N/AR | Beretta Mynute | Contrasted |
| Beretta 28 CAI N | Beretta Mynute | Contrasted |
| Beretta 28 CSI N/AR | Beretta Mynute | Contrasted |
| Beretta 25 CSI | Beretta Mynute Sinthesi | Contrasted |
| Beretta 29 CSI | Beretta Mynute Sinthesi | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part R10030294 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10030294. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge R10030294 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge remains fixed, regardless of what happens in the circuit.
Cause: The clock mechanism gets stuck over time and does not reflect the actual pressure.
Bleed a radiator or add water to the circuit and observe if the needle reacts before considering that the part is damaged.
- 02
The temperature gauge shows a value that does not match the display of the boiler.
Cause: The bellows or the capillary that measures the temperature loses accuracy with use.
Compare the reading with the thermostat or the boiler panel to ensure that the fault does not come from the sensor.
- 03
The display is scratched, fogged, or broken, preventing the reading of pressure and temperature.
Cause: The plastic of the sphere is vulnerable to impacts and the heat from the boiler.
Shine a flashlight to see if the needle responds well behind the scratching; if it's just the glass, assess whether it's worth replacing the entire part.
- 04
It is suspected that the circuit is gradually losing pressure and a new instrument is wanted to confirm this.
Cause: With the needle blocked or misaligned, you cannot rely on whether the pressure drop is real or if it is a problem with the part.
Leave the boiler off for a few hours and note if the indicated pressure changes: if there are no variations, the problem may be with the manometer and not a leak.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta pressure gauge R10030294
- Catalogue reference
- R10030294
- Brand
- Beretta
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Part reference
- R10030294
- Temperature range
- 0-120 °C
- Pressure range
- 0-4 bar