Beretta Mynute thermohydrometer Ref. R10030294 · Ø42, 0–120 °C / 0–4 bar

Beretta Mynute thermohydrometer Ref. R10030294 · Ø42, 0–120 °C / 0–4 bar

Sphere thermohygrometer with dual needle, for simultaneous reading of temperature (0-120 °C) and pressure (0-4 bar) in the boiler circuit. The sphere does not have the manufacturer's name printed nor any code other than the reference R10030294. Replacement requires first confirming the fault of the part through technical diagnosis, even when it stops measuring accurately or the display breaks.

Catalogue reference
R10030294
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Beretta boilers compatible with reference R10030294

Pressure gauge with reference R10030294. Eight confirmed compatibilities: 18 CSI AR and 24 CAI AR.

Proven compatibility

Boiler modelFamilyVerification
Beretta 18 CSI ARBeretta MynuteContrasted
Beretta 24 CAI ARBeretta MynuteContrasted
Beretta 24 CAI NBeretta MynuteContrasted
Beretta 24 CSI N/ARBeretta MynuteContrasted
Beretta 28 CAI NBeretta MynuteContrasted
Beretta 28 CSI N/ARBeretta MynuteContrasted
Beretta 25 CSIBeretta Mynute SinthesiContrasted
Beretta 29 CSIBeretta Mynute SinthesiContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10030294 is the one for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10030294. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the manometer R10030294

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge remains fixed, regardless of what happens in the circuit.

    Cause: The clock mechanism gets stuck over time and does not reflect the actual pressure.

    Bleed a radiator or add water to the circuit and observe if the needle reacts before considering that the part is damaged.

  • 02

    The temperature gauge shows a value that does not match the display of the boiler.

    Cause: The bellows or the capillary that measures the temperature loses accuracy with use.

    Compare the reading with the thermostat or the boiler panel to ensure that the fault does not come from the sensor.

  • 03

    The display is scratched, fogged, or broken, preventing the reading of pressure and temperature.

    Cause: The plastic of the sphere is vulnerable to impacts and the heat from the boiler.

    Shine a flashlight to see if the needle responds well behind the scratching; if it's just the glass, assess whether it's worth replacing the entire part.

  • 04

    It is suspected that the circuit is gradually losing pressure and a new instrument is wanted to confirm this.

    Cause: With the needle blocked or misaligned, you cannot rely on whether the pressure drop is real or if it is a problem with the part.

    Leave the boiler off for a few hours and note if the indicated pressure changes: if there are no variations, the problem may be with the manometer and not a leak.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta pressure gauge R10030294

Catalogue reference
R10030294
Uniclima internal SKU
MDPTBCIAO24
Brand
Beretta
Type of part
Pressure gauges & aquastats
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Part reference
R10030294
Temperature range
0-120 °C
Pressure range
0-4 bar
Frequently Asked Questions

Frequently asked questions about the pressure gauge R10030294

Does this thermohygrometer Ref. R10030294 have the manufacturer's name on the dial?
No; the dial does not have the manufacturer's name printed on it nor any code other than the reference R10030294.
What does the thermohygrometer Ref. R10030294 measure?
Temperature, from 0 to 120°C, and pressure, from 0 to 4 bar, on the same dial with dual needle.
When should this thermohydrometer be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when it stops indicating accurately or the display breaks.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Beretta Mynute thermohydrometer Ref. R10030294 · Ø42, 0–120 °C / 0–4 bar