Capillary Manometer 0-4 Bar Boiler THELIA 30 E Ref. 05600500
The 0-4 bar capillary manometer of the THELIA 30 E boiler measures and controls the pressure of the circuit, ensuring proper operation. When it fails, you may notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This manometer is compatible with several models, including the TWIN F 24 E, TWIN F 28 E, THELIA TWIN 28 E, and SYLVA 24 E. It is recommended to replace it if you observe issues with pressure or temperature measurement.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05600500
Pressure gauge with reference 05600500. 11 verified compatibilities: TWIN F 24 E and TWIN F 28 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval TWIN F 24 E | TWIN | Contrasted |
| Saunier Duval TWIN F 28 E | TWIN | Contrasted |
| Saunier Duval TWIN C 24 E | TWIN | Contrasted |
| Saunier Duval TWIN C 28 E | TWIN | Contrasted |
| Saunier Duval MASTER TWIN L 85 E | TWIN | Contrasted |
| Saunier Duval THELIA TWIN 28 E | THELIA TWIN | Contrasted |
| Saunier Duval THEMIS TWIN 28 E | THEMIS TWIN | Contrasted |
| Saunier Duval THEMIS TWIN 28 EV | THEMIS TWIN | Contrasted |
| Saunier Duval SYLVA 24 E | SYLVA | Contrasted |
| Saunier Duval SYLVA 24 EV | SYLVA | Contrasted |
| Saunier Duval SYLVA FF 24 E | SYLVA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05600500 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05600500. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge 05600500 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle does not move from zero even though the boiler is loaded and running.
Cause: The capillary that carries the pressure to the gauge is blocked or the mechanism is jammed.
Follow the path of the capillary tube looking for any bends or crushing before considering the manometer as faulty.
- 02
The thin tube coming from the pressure gauge is bent, crushed, or broken.
Cause: The capillary is the only pathway for the pressure signal to reach; if it is pinched or broken, the gauge stops receiving information even if the rest of the circuit is functioning properly.
Check if the capillary tube got trapped between sheets or cables when assembling or disassembling the boiler casing.
- 03
Water or moisture appears at the fitting where the capillary joins the circuit.
Cause: The gasket of that fitting has degraded and is allowing water to pass through at low pressure.
Tighten the fitting carefully, dry the area, and check if it becomes damp again before replacing the part.
- 04
The dial is broken or so scratched that the needle is indistinguishable.
Cause: A previous handling impact has damaged the watch's crystal or body.
Check that the damage is only cosmetic on the glass, without affecting the capillary, before replacing the entire assembly.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval pressure gauge 05600500
- Catalogue reference
- 05600500
- Brand
- Saunier Duval
- Type of part
- Pressure gauges - Aquastats
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure range
- 0-4 bar
- Type of pressure gauge
- Capillary, with metal connection fitting
- Dial color
- White
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval TWIN C 28 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.