When you open the tap or turn on the heating, the Huba Control 502.99016 pressure sensor for the Fagor FE 20 E-2 N boiler is responsible for measuring and controlling the pressure of the circuit. If this part fails, you will notice incorrect readings, which can cause the boiler to lock due to a false lack of pressure or not regulate the temperature properly. This sensor is compatible with several models from the Ecocompact and EcoCompact FEE ranges, among others. It is advisable to replace it when you observe these symptoms to avoid bigger problems.

VAT included

Compatibility

Fagor boilers compatible with reference FA000170

Pressure gauge with reference FA000170. 38 verified compatibilities: FE18E/1 B and FE18E/1 N.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE18E/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE18E/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE20E/2 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE20E/2 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE20EF/2 LPGEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE20EF/2 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24E/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24E/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24E H/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24EC/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24EC/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24EMA/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE24EMA/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE26E/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE26E/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE27E/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE27E/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE27ECN/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE27EMA/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE27EMA/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE28E/1 BEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE35EMA/1 NEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FE35EMA/1GLPEcocompact / FE (sealed wall-hung combi)Contrasted
Fagor FEE20/2 BEcoCompact FEE / SuperCompactContrasted
Fagor FEE20/2 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE24MA/1 BEcoCompact FEE / SuperCompactContrasted
Fagor FEE24MA/1 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE26MA/1 BEcoCompact FEE / SuperCompactContrasted
Fagor FEE26MA/1 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE27MA/1 BEcoCompact FEE / SuperCompactContrasted
Fagor FEE27MA/1 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE28/1 BEcoCompact FEE / SuperCompactContrasted
Fagor FEE35MA/1 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE35MA/1GLPEcoCompact FEE / SuperCompactContrasted
Fagor FEE40MA/1 NEcoCompact FEE / SuperCompactContrasted
Fagor FEE40MA/1GLPEcoCompact FEE / SuperCompactContrasted
Fagor FES28AE/1 BFES (superior series)Contrasted
Fagor FES28AE/1 NFES (superior series)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. FA000170 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference FA000170. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge FA000170 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure on the display shows 0 or dashes, even though the circuit is full.

    Cause: The sensor does not send a signal to the PCB, which does not receive any pressure value and shows an error.

    Check for leaks in the circuit or in the safety valve before considering the sensor.

  • 02

    The boiler locks out due to low pressure just after refilling the circuit.

    Cause: The sensor may be giving a false reading below the actual level, which causes the lockout even though the water is at the correct level.

    Check the pressure with a separate manometer if possible, to rule out that it is a reading issue and not a water problem.

  • 03

    If I move the wiring of the boiler a little, the pressure reading changes immediately.

    Cause: This indicates a possible loose connection in the connector or in the cable of the sensor.

    Carefully move the sensor connector while watching the display, without forcing or disconnecting it while hot.

  • 04

    The boiler does not start and gives a warning of low pressure, even though the circuit is properly filled.

    Cause: The PCB relies on the signal from the sensor to determine if there is enough water; if the signal is incorrect, it does not allow the start-up even if everything is correct.

    Bleed the radiators and confirm the actual pressure before replacing the sensor, especially if the installation is new or has just been tampered with.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor FA000170 pressure gauge datasheet

Catalogue reference
FA000170
Brand
Fagor
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure range
0...4 bar
Maximum pressure
8 bar
Power supply
8.5...30 VDC
Manufacturer code
502.99016
Frequently Asked Questions

Frequently asked questions about the pressure gauge FA000170

Is the sensor 502.99016 of the Fagor FE 20 E-2 N a thermomanometer?
No; the catalog referred to it this way, but the label only shows electrical specifications, without any mechanical measurement elements or temperature. It is an electronic pressure sensor.
What pressure range does the Huba Control 502.99016 sensor support?
It measures from 0 to 4 bar, with a maximum allowable of 8 bar.
Who manufactures this pressure sensor for the Fagor FE 20 E-2 N?
Huba Control, as stated directly on the label.
Does this sensor also fit the Fagor FE 24 EC-1 N?
Yes, it is on the compatibility list along with other models from the FE/FEE range, including FE 24 EC-1 B and FE 24 EC-1 N.
How is the pressure sensor of the Fagor FE 20 powered?
A 8.5-30VDC, with an analog output signal proportional to the pressure.