Pressure gauge Baxi Roca Victoria 20/20 and Baxi Laura 20/20

Pressure gauge Baxi Roca Victoria 20/20 and Baxi Laura 20/20

Stock · 1 unit

When you open the tap or start the heating, the Roca Victoria 20/20 and Baxi Laura 20/20 pressure gauge provides you with the necessary information about the circuit pressure. This component, with reference 122152600, measures and controls the pressure, ensuring that the boiler operates correctly. If the pressure gauge fails, you will notice incorrect readings, which can lead to the boiler locking out due to a false lack of pressure or not regulating the temperature properly. It is compatible with Roca Victoria and Baxi Laura boilers, among others. It is recommended to replace it if you notice that it does not show the correct pressure or if it has visible damage.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 122152600

Pressure gauge with reference 122152600. Two confirmed compatibilities: Laura and Victoria.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca LauraLauraContrasted
Baxi Roca VictoriaVictoriaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 122152600 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122152600. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge 122152600 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The needle of the manometer does not move even when you bleed pressure from the circuit.

    Cause: The internal mechanism that translates water pressure into needle movement has become blocked, usually due to scale buildup inside the pressure gauge.

    Bleed a radiator with the pressure gauge in view; if the boiler indicates low pressure by other means and the needle does not move, the pressure gauge is the one that is faulty.

  • 02

    The pressure gauge always reads zero, even though the circuit has just been filled and the boiler is operating normally.

    Cause: The mechanism may have a broken or disconnected part, so it does not translate the actual pressure on the scale.

    Note that the boiler does not give any warning of low pressure during normal operation; if everything is fine except for the pressure gauge reading, the problem is only with the part.

  • 03

    The pressure gauge reading fluctuates without anyone having touched the circuit, rising and falling for no apparent reason.

    Cause: A leak or internal fault in the pressure gauge mechanism causes unstable readings that do not correspond to the actual water pressure.

    Record the pressure first thing in the morning, when cold, over several days; if it varies significantly without any changes in the installation, suspect the pressure gauge before a leak in the circuit.

  • 04

    It is suggested to replace the pressure gauge during a maintenance check because the reading is no longer reliable, even if there is no obvious fault.

    Cause: Over the years, the mechanism progressively loses accuracy, and a reading that gradually deviates from reality is harder to detect than a sudden fault.

    Compare the pressure gauge reading with the actual behavior of the boiler (whether it locks out due to pressure or not) before replacing it solely due to age.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Baxi Roca pressure gauge 122152600

Catalogue reference
122152600
Brand
Baxi Roca
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Scale
0-4 bar
Frequently Asked Questions

Frequently asked questions about the pressure gauge 122152600

Is this pressure gauge suitable for a Baxi Roca Victoria 20/20?
Yes, the Victoria 20/20 is on the list of compatible boilers in this datasheet.
What pressure scale does this manometer have?
From 0 to 4 bar, according to the gauge.
Is this pressure gauge suitable for a Baxi Roca Victoria 20, without the /20?
Yes, the Victoria 20 is listed among the compatible boilers on this datasheet.

Spare parts related to Baxi Roca Laura

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure gauge Baxi Roca Victoria 20/20 and Baxi Laura 20/20