Water Pressure Switch Boiler Cointra Domitop F24 E - Microswitch V-S610R-041

Water Pressure Switch Boiler Cointra Domitop F24 E - Microswitch V-S610R-041

Stock · 1 unit

The water pressure switch of the Cointra Domitop F24 E boiler, reference I39806180, is responsible for checking the water pressure and authorizing the operation of the boiler. If it fails, the boiler will not start or will lock out, even if the actual pressure is correct, which can generate the fault code F37: incorrect water circuit pressure (low). This component is compatible with models such as Domitop F 24 D, Domitop C 24 E, among others in the Cointra/Ferroli range. It should be replaced when these malfunction symptoms are detected.

VAT included

Compatibility

Cointra boilers compatible with reference I39806180

Pressure switch with reference I39806180. Six confirmed compatibilities: Domitop F 24 E and Domitop F 24 D.

Proven compatibility

Boiler modelFamilyVerification
Cointra Domitop F 24 ECointra/Ferroli DomitopContrasted
Cointra Domitop F 24 DCointra/Ferroli DomitopContrasted
Cointra Domitop C 24 ECointra/Ferroli DomitopContrasted
Cointra Domitop F 30Cointra/Ferroli DomitopContrasted
Cointra Domitop F 30 ECointra/Ferroli DomitopContrasted
Cointra Domitop C 30 ECointra/Ferroli DomitopContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. I39806180 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference I39806180. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch I39806180 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start and the pressure gauge shows normal pressure, but it gives a pressure fault.

    Cause: The micro switch of the water pressure switch may be open even if the actual pressure is correct.

    Bleed the air from the radiators and adjust the pressure to the value indicated by the boiler before considering the pressure switch as faulty.

  • 02

    A warning for low pressure lights up intermittently, without the boiler completely locking out.

    Cause: A micro switch with oxidized or worn contacts can give false low pressure alerts even if the circuit is functioning properly.

    Measure the cold pressure with the boiler's manometer and repeat the reading after a few minutes to rule out a real fluctuation.

  • 03

    The boiler stops in the middle of operation and needs to be refilled or reset to work again.

    Cause: If the circuit loses pressure due to a leak, the pressure switch cuts off the gas supply as a safety measure even if it is in good condition.

    Check the bleed valves, safety valve, and radiators for any leaks before replacing the pressure switch.

Fault codes for Cointra that this part resolves.

CodeFaultDiagnosis and solution
F37Incorrect water circuit pressure (low).The water pressure switch is disconnected, faulty, or does not close at the minimum pressure, so the PCB does not confirm sufficient pressure; check the continuity of the pressure switch with ~1–1.5 bar on the pressure gauge and its wiring, and it can be bypassed for diagnostic purposes only.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Cointra pressure switch I39806180

Catalogue reference
I39806180
Brand
Cointra
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Microswitch model
V-S610R-041
Electrical classification
1.5A-250VAC
Batch code
Y170
Additional code
0516PS
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch I39806180

What faults require the replacement of the water pressure switch Cointra Domitop F24 E, reference PACCDF24E?
It is replaced when the boiler does not start due to insufficient water pressure fault, or when the V-S610R-041 microswitch fails.
What boiler models are compatible with the Cointra Domitop F24 E water pressure switch?
It is compatible with the models: Domitop F 24 E, Domitop F 24 D, Domitop C 24 E, Domitop F 30, Domitop F 30 E, and Domitop C 30 E.
What fault code is associated with this pressure switch?
The documented fault code for this product is F37.
Is this pressure switch suitable for boilers from other brands?
No, this pressure switch is specifically designed for the Cointra/Ferroli Domitop range.
How many models are compatible with the Cointra Domitop F24 E water pressure switch?
A total of 6 models are compatible with this pressure switch.

Spare parts related to Cointra Cointra/Ferroli Domitop

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model