Grundfos Circulating Pump UPS 15-50 A0 For Ferroli Domiproject F24 D · P/N 59965500
Grundfos circulating pump, model UPS 15-50 A0, originally installed in Ferroli boilers with factory reference P/N 59965500. It circulates the water in the heating circuit. It is replaced due to noise, blockage (seized), loss of flow, or leakage, which are typical symptoms of wear for this type of pump.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 39847401
Circulating pump with reference 39847401. 17 verified compatibilities: DOMIPROJECT F24 D and DOMICOMPACT F24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli DOMIPROJECT F24 D | Domiproject | Contrasted |
| Ferroli DOMICOMPACT F24 | Domicompact | Contrasted |
| Ferroli DIVATECH C24 | Divatech | Contrasted |
| Ferroli DIVATECH F24 | Divatech | Contrasted |
| Ferroli DIVATECH micro F24 | Divatech | Contrasted |
| Ferroli DIVATECH micro LN F24 D | Divatech | Contrasted |
| Ferroli DIVATECH MICRO LN F32 D | Divatech | Contrasted |
| Ferroli DIVATOP F24 | Divatop | Contrasted |
| Ferroli DIVATOP LOW NOx F24 | Divatop | Contrasted |
| Ferroli DOMICONDENS F24 D | Domicondens | Contrasted |
| Ferroli DOMICONDENS F28 D | Domicondens | Contrasted |
| Ferroli BLUEHELIX PRO 25 C | Bluehelix | Contrasted |
| Ferroli BLUEHELIX TECH 25 C | Bluehelix | Contrasted |
| Ferroli BLUEHELIX TECH 25A | Bluehelix | Contrasted |
| Ferroli ECONCEPT SOLAR 25 | Econcept | Contrasted |
| Ferroli ECONCEPT TECH 25A | Econcept | Contrasted |
| Ferroli ECONCEPT TECH 25C | Econcept | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39847401 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39847401. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump 39847401 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The radiators are not heating properly, although the domestic hot water is working correctly.
Cause: If the impeller does not rotate properly, the heating circuit does not receive enough flow, even though the burner is functioning well.
Check that the pump speed selector is not in the minimum position before considering it faulty.
- 02
The pump makes noise, with vibrations or humming, especially when turning on the heating.
Cause: Trapped air or the accumulation of scale in the impeller disrupt its rotation and cause noise.
Bleed the heating circuit using the highest bleed valve in the installation before changing the pump.
- 03
After leaving the boiler off for a while, like in summer, the pump does not start again.
Cause: The shaft can seize due to sediment if it does not rotate for a long time.
Locate the central bleed screw of the rotor and turn it by hand with a screwdriver to try to unlock the shaft.
- 04
There is water leaking at the base or the shaft of the pump, with limescale stains around it.
Cause: The mechanical seal wears out with use and allows water to pass through the shaft.
Dry the area well and check again after a while of operation to confirm that the leak is coming from the shaft.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A03 | Overtemperature protection operation | If the circulation pump is blocked or not providing flow, water does not circulate through the circuit and the temperature rises until the safety is triggered. Check that the pump is rotating and recirculating (free shaft, voltage present, and hot return) and bleed air. |
| F43 | Activation of the heat exchanger protection | The absence of circulation due to a pump fault causes localized overheating of the heat exchanger. Check the rotation/electrical consumption of the pump and ensure there is a temperature difference between the flow and return; if not, inspect or replace the pump. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli circulator pump 39847401
- Catalogue reference
- 39847401
- Brand
- Ferroli
- Type of part
- Pumps
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Grundfos
- Model (Type)
- UPS 15-50 A0
- Ferroli Reference (P/N)
- 59965500
- PC code
- 9739
- Voltage / frequency
- 230V~ 50Hz
- Condenser
- 2 µF
- Degree of protection
- IP44
- Thermal class
- Class H / TF95
- Maximum pressure
- max. 3 bar
- Current / power by speed
- I: 0.18A-40W · II: 0.29A-65W · III: 0.39A-90W
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Domiproject F24 D Manual (PDF)Document © Ferroli, provided as a technical reference.