Wilo Circulating Pump for Ferroli Bluehelix Pro 32 C Ref. 39820902
RefurbishedFerroliPumpsWilo

Wilo Circulating Pump for Ferroli Bluehelix Pro 32 C Ref. 39820902

Stock · 1 unit

Circulator pump for the Ferroli Bluehelix Pro 32 C boiler, also compatible with Divaproject, Divatop Micro, Divatech, Domicompact, Domiproject, Domitech, and FEReasy. Manufactured by Wilo (Wilo Intec, France), model FRSL15/6 HE-3 KU C. It circulates water in the system with three speeds, up to 86W. It is replaced when the boiler does not heat or the pump does not start.

VAT included

Compatibility

Ferroli boilers compatible with reference 39820902

Circulating pump with reference 39820902. Eight confirmed compatibilities: PRO 32 C and DIVAPROJECT.

Proven compatibility

Boiler modelFamilyVerification
Ferroli PRO 32 CBLUEHELIXContrasted
Ferroli DIVAPROJECTDIVAPROJECTContrasted
Ferroli MICRO (F32)DIVATOPContrasted
Ferroli (C32 / F32)DIVAtechContrasted
Ferroli DOMICOMPactDOMICOMPactContrasted
Ferroli (C32 / F32)DOMIPROJECTContrasted
Ferroli (C32 / F32)DOMITECHContrasted
Ferroli FEReasyFEReasyContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 39820902 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 39820902. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump 39820902 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler turns on, but the heating does not heat or takes a long time to do so.

    Cause: If the pump is at the lowest speed or running weakly, the flow may not be sufficient for the circuit.

    Check the speed at which the pump is set (selector on the body) before declaring it faulty.

  • 02

    There is noise or vibration in the pump, more noticeable at some of the speeds.

    Cause: A rotor with scale or trapped air often vibrates more at certain speed positions.

    Change the speed and bleed the air from the pump through the front screw before replacing it.

  • 03

    The pump does not start at any of the three speeds.

    Cause: The motor may be jammed or not receiving power from the PCB, regardless of the selected speed.

    Check that power is reaching the pump in all three positions of the selector before purchasing a new one.

  • 04

    The boiler is displaying a fault code related to circulation or pressure differential.

    Cause: The control unit detects that there is not enough flow and blocks the boiler for safety reasons to avoid damaging the heat exchanger.

    Before changing the pump, bleed the circuit well and make sure that the radiator valves are not closed.

Fault codes for Ferroli that this part resolves.

CodeFaultDiagnosis and solution
A03Overtemperature protection activation.If the circulating pump (ref. 39820902) is blocked/faulty or does not start, the water does not circulate and the primary overheats. Check order/voltage at terminals, ensure the rotor turns, and bleed the circuit.
F43Activation of the heat exchanger protection.A null or very low circulation due to pump fault/blockage activates the heat exchanger protection. Check the power supply and rotation of the pump and ensure there is flow in the primary circuit.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Ferroli 39820902 circulation pump.

Catalogue reference
39820902
Brand
Ferroli
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Voltage/frequency
230V~ 50Hz
Condenser
2.6 µF
Degree of protection
IP44
Thermal class
Class F / TF95
Nominal pressure
PN6
Current/power by speed
I: 0.20A-42W | II: 0.29A-63W | III: 0.39A-86W
Manufacturer and plant
Made by Wilo Intec, 50 av E. Casella, F-18700 Aubigny/Nère, Made in EU
Manufacturer code / reference
Typ FRSL15/6 HE-3 KU C | N° 4528896 | Réf 36602710 FLP
Frequently Asked Questions

Frequently asked questions about the circulator pump 39820902

Is the pump of the Bluehelix Pro 32 C original from Ferroli?
No; the label indicates that the manufacturer is Wilo (Wilo Intec, France); it is sold as a compatible spare part with Ferroli.
What code should I check on the pump of my Ferroli Divatop Micro F32?
The type Wilo FRSL15/6 HE-3 KU C, No. 4528896, Ref 36602710 FLP, printed on the label.
How many speeds does this pump have for the Ferroli Domiproject C32/F32?
Three speeds, with 42W, 63W, and 86W of consumption depending on the setting.
What pressure and temperature does the pump of the Ferroli Domitech C32/F32 operate at?
PN6 and up to TF95 of maximum fluid temperature, according to the marking.
Is this Wilo pump suitable for the Ferroli FEReasy in addition to the Bluehelix Pro 32 C?
Yes, FEReasy is on the list of compatible boilers, along with Divaproject, Divatop Micro F32, Divatech C32/F32, Domicompact, Domiproject C32/F32, and Domitech C32/F32.

Spare parts related to Ferroli BLUEHELIX

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Wilo Circulating Pump for Ferroli Bluehelix Pro 32 C Ref. 39820902