Vaillant Safety Valve 10 Bar VMI 32/362-7 Ref. 190745
The safety valve releases water if the circuit pressure exceeds the limit, usually 3 bar. When it fails, you may notice that it drips continuously or that it does not discharge when it should. This valve is compatible with several Vaillant boiler models, such as the VMI 280-7, VMI 282-7, and VMI 32/362-7, among others. A technician should confirm through diagnosis whether it needs to be replaced if you observe these symptoms to avoid further issues in the system.
- Type of part
- Safety valves
- Status
- Refurbished
- Catalogue reference
- 190745
- Warranty
- 1 year
Vaillant boilers compatible with reference 190745
Safety valve with reference 190745. Eight confirmed compatibilities: VMI 280-7 and VMI 280-7 R3.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMI 280-7 | Aquablock VMI | Contrasted |
| Vaillant VMI 280-7 R3 | Aquablock VMI | Contrasted |
| Vaillant VMI 282-7 | Aquablock VMI | Contrasted |
| Vaillant VMI 282-7 R2 | Aquablock VMI | Contrasted |
| Vaillant VMI 282-7 R3 | Aquablock VMI | Contrasted |
| Vaillant VMI 32/362-7 | Aquablock VMI | Contrasted |
| Vaillant VMI 32/362-7 R3 | Aquablock VMI | Contrasted |
| Vaillant VIH CL 20 S | Aquablock VIH | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 190745 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 190745. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the safety valve 190745
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve is leaking continuously even though the circuit is at normal operating pressure.
Cause: The internal seat loses tightness over time and allows a constant trickle of water to pass through.
Check the pressure on the manometer: if it is within the normal range for this boiler and it is still dripping, the issue is with the gas valve closure.
- 02
The pressure in the circuit rises and the valve does not open or release water.
Cause: If the mechanism is jammed due to scale or dirt, the spring cannot move the shutter when it reaches the setting point.
With the cold installation, operate the manual bleed lever to check if the mechanism moves easily.
- 03
After firing once, the gas valve keeps dripping without closing again.
Cause: A particle dragged during firing can become lodged in the seat and prevent complete closure.
Bleed the valve manually a couple more times: sometimes this drags out dirt and restores the sealing.
- 04
The pressure in the circuit needs to be replenished more frequently than usual.
Cause: A slow drip from the valve is lost down the drain without leaving a visible puddle, but it gradually reduces pressure.
Place a container under the drain pipe for an entire night to check if it collects water.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Vaillant safety valve 190745
- Catalogue reference
- 190745
- Uniclima internal SKU
- VSMAVMI362
- Brand
- Vaillant
- Type of part
- Safety valves
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Connection
- 1/2"
- Setpoint
- 10 bar
- TÜV certification code
- TÜV-SV-00-615
- Body material
- CW617N — brass alloy EN 12165 (not a manufacturer brand)
- CW617N is a designation for a brass alloy (standard EN 12165), not a manufacturer brand.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Vaillant VMI 282-7 R2 Manual (PDF) Document © Vaillant, provided as a technical reference.