ITW Ispracontrols transformer BW12026-00 - Chaffoteaux TIG 35 HP Ref. 61002105
RefurbishedChaffoteauxTransformersITW

ITW Ispracontrols transformer BW12026-00 - Chaffoteaux TIG 35 HP Ref. 61002105

Stock · 5 units

ITW Ispracontrols ignition transformer, type BW12026-00, for 220-240V supply at 50-60Hz, 3VA, and a maximum temperature of 90°C, with CE marking. It is used in Chaffoteaux TIG 35 HP boilers and related models from the Calydra, Celtic, Minima, Nectra, Niagara Delta, Pigma Green, and Talia Green ranges. It is replaced when the boiler fails to ignite due to a lack of spark at the ignition electrode.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 61002105-20

Ignition transformer with reference 61002105-20. 31 verified compatibilities: Calydra 23 CF/FF (N/P) and Calydra 28 CF/FF (N/P).

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Calydra 23 CF/FF (N/P)CalydraContrasted
Chaffoteaux Calydra 28 CF/FF (N/P)CalydraContrasted
Chaffoteaux Calydra VMC 23CalydraContrasted
Chaffoteaux Calydra Delta 24 CF/FF/VMCCalydraContrasted
Chaffoteaux Calydra Delta 28 CF/FFCalydraContrasted
Chaffoteaux Calydra Green 24CalydraContrasted
Chaffoteaux Calydra Green 30CalydraContrasted
Chaffoteaux Nectra 1.23NectraContrasted
Chaffoteaux Nectra 2.23NectraContrasted
Chaffoteaux Nectra 2.28NectraContrasted
Chaffoteaux Elexia Comfort 24 CF/FFElexiaContrasted
Chaffoteaux Elexia II 2.23 CF/FFElexiaContrasted
Chaffoteaux Hyxia 23 VMC/FFHyxiaContrasted
Chaffoteaux Hyxia 28 CF/FFHyxiaContrasted
Chaffoteaux Centora 2.24CentoraContrasted
Chaffoteaux Centora 2.28CentoraContrasted
Chaffoteaux Centora 3.24CentoraContrasted
Chaffoteaux Centora Green 2.24CentoraContrasted
Chaffoteaux Mira Comfort 24/30LookContrasted
Chaffoteaux Mira Green 24/30/35LookContrasted
Chaffoteaux Niagara CNiagaraContrasted
Chaffoteaux Niagara DeltaNiagaraContrasted
Chaffoteaux Niagara Green 24NiagaraContrasted
Chaffoteaux Aludra Delta 24 CF/FFAludra DeltaContrasted
Chaffoteaux Aludra Delta 28 FFAludra DeltaContrasted
Chaffoteaux Celtic 1.23CelticContrasted
Chaffoteaux Celtic 2.23CelticContrasted
Chaffoteaux Celtic Turbo 2.20CelticContrasted
Chaffoteaux Talia Green SystemTalia GreenContrasted
Chaffoteaux Pigma Green 25/30/35Pigma GreenContrasted
Chaffoteaux Urbia Green 25/30/35Urbia GreenContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61002105-20 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61002105-20. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 61002105-20 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite but the flame does not light.

    Cause: The transformer should provide the high voltage necessary for the spark to jump at the electrode. If there is not enough voltage, the spark that ignites the gas will not occur.

    First, check that the high voltage cable is properly connected to both the transformer and the electrode, and that there are no visible breaks.

  • 02

    There is no spark at the ignition electrode.

    Cause: This directly indicates that the transformer is not generating the necessary voltage to create the arc.

    Make sure that the electrode is properly aligned and that the tip is not worn or broken before changing the transformer.

  • 03

    The boiler locks out due to an ignition fault on the first or second start attempt.

    Cause: If there is no arc in the electrode, the control board does not detect the flame within the safety time and locks the boiler.

    Also check that gas is reaching the burner (there should be a brief smell when trying to start) to rule out that the blockage is due to another cause.

  • 04

    The fault always occurs when starting up, never when the boiler is already running.

    Cause: The transformer only operates when the boiler is turned on; if it fails at that moment, the problem is always in the ignition phase.

    If the boiler is working well and maintains the flame once ignited, the fault is almost certainly in the ignition phase, not in the burner that is already lit.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
70-80The boiler does not ignite because it does not detect the flame.The ignition transformer is not sending the high voltage needed to the electrode, so the spark does not occur and the boiler locks out. Check that the transformer is receiving about 230 V while trying to ignite and that there is no spark. If it is receiving power but there is no spark, the transformer is faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux Ignition Transformer Datasheet 61002105-20

Catalogue reference
61002105-20
Brand
Chaffoteaux
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
ITW Ispracontrols
Type
BW12026-00
Voltage
220-240V
Frequency
50-60Hz
Power
3VA
Temperature
T.90°C
Date code
3704G
Batch code
14451
Certification
CE + VDE type symbol
Frequently Asked Questions

Frequently asked questions about the ignition transformer 61002105-20

Does this transformer Ref. 61002105 work for a Chaffoteaux Niagara Delta 24 FF?
Yes, the Niagara Delta 24 FF is on the list of compatible models, which also includes TIG 35 HP CF, Calydra 28 CF/FF, Celtic 1.23, Nectra 2.23, Pigma Green 25/30 FF, and Talia Green System.
Who manufactures the transformer BW12026-00 for the Chaffoteaux TIG 35 HP?
ITW Ispracontrols, according to the marking TYPE: BW12026-00 printed on the part label.
What voltage does the transformer of the TIG 35 HP need?
According to the label, 220-240V at 50-60Hz, 3VA, with a maximum operating temperature of 90°C.
How can I distinguish this transformer from another similar model by Chaffoteaux?
By the code type BW12026-00 next to the ITW Ispracontrols logo printed on the label.
What fault does replacing the ITW Ispracontrols transformer of the TIG 35 HP resolve?
The lack of spark at the ignition electrode, which prevents the boiler from igniting.
How many models are compatible with the transformer TETIG35HP?
The TETIG35HP transformer is compatible with a total of 31 models from different ranges.

Spare parts related to Chaffoteaux Calydra

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
ITW Ispracontrols transformer BW12026-00 - Chaffoteaux TIG 35 HP Ref. 61002105