ITW BW12026-00 Transformer For Chaffoteaux Calydra 28 FF
RefurbishedChaffoteauxTransformersITW

ITW BW12026-00 Transformer For Chaffoteaux Calydra 28 FF

Stock · 5 units

Transformer for Chaffoteaux Calydra 28 FF boilers and other compatible Chaffoteaux models. Manufactured by ITW, with code BW12026-00 printed on the label. Operates at 220-240 Vac 50-60 Hz, with a power of 3 VA and a maximum allowable temperature of +90°C. It should be replaced if it stops correctly transforming the supply voltage.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 61002105-20

Ignition transformer with reference 61002105-20. 31 verified compatibilities: Calydra 23 CF/FF (N/P) and Calydra 28 CF/FF (N/P).

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Calydra 23 CF/FF (N/P)CalydraContrasted
Chaffoteaux Calydra 28 CF/FF (N/P)CalydraContrasted
Chaffoteaux Calydra VMC 23CalydraContrasted
Chaffoteaux Calydra Delta 24 CF/FF/VMCCalydraContrasted
Chaffoteaux Calydra Delta 28 CF/FFCalydraContrasted
Chaffoteaux Calydra Green 24CalydraContrasted
Chaffoteaux Calydra Green 30CalydraContrasted
Chaffoteaux Nectra 1.23NectraContrasted
Chaffoteaux Nectra 2.23NectraContrasted
Chaffoteaux Nectra 2.28NectraContrasted
Chaffoteaux Elexia Comfort 24 CF/FFElexiaContrasted
Chaffoteaux Elexia II 2.23 CF/FFElexiaContrasted
Chaffoteaux Hyxia 23 VMC/FFHyxiaContrasted
Chaffoteaux Hyxia 28 CF/FFHyxiaContrasted
Chaffoteaux Centora 2.24CentoraContrasted
Chaffoteaux Centora 2.28CentoraContrasted
Chaffoteaux Centora 3.24CentoraContrasted
Chaffoteaux Centora Green 2.24CentoraContrasted
Chaffoteaux Mira Comfort 24/30LookContrasted
Chaffoteaux Mira Green 24/30/35LookContrasted
Chaffoteaux Niagara CNiagaraContrasted
Chaffoteaux Niagara DeltaNiagaraContrasted
Chaffoteaux Niagara Green 24NiagaraContrasted
Chaffoteaux Aludra Delta 24 CF/FFAludra DeltaContrasted
Chaffoteaux Aludra Delta 28 FFAludra DeltaContrasted
Chaffoteaux Celtic 1.23CelticContrasted
Chaffoteaux Celtic 2.23CelticContrasted
Chaffoteaux Celtic Turbo 2.20CelticContrasted
Chaffoteaux Talia Green SystemTalia GreenContrasted
Chaffoteaux Pigma Green 25/30/35Pigma GreenContrasted
Chaffoteaux Urbia Green 25/30/35Urbia GreenContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61002105-20 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61002105-20. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 61002105-20 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely dead: no pilot lights or the control panel turn on, as if it has no power.

    Cause: The transformer does not deliver the necessary current to power the PCB, and without it, the boiler does not start.

    Measure with a multimeter if there is current at the terminals of the primary of the transformer before considering it faulty.

  • 02

    The boiler turns off by itself intermittently, especially after it has been running for a while and has heated up.

    Cause: A transformer with damaged winding loses current when it heats up, and the PCB loses stable power supply.

    Leave the boiler on for a while and measure the output current of the secondary when it starts to fail, to see if it decreases.

  • 03

    A fuse blows every so often, or the boiler stops and restarts by itself after a few minutes.

    Cause: An internal short circuit in the transformer, or an overload downstream, activates the thermal protection of the transformer.

    Before changing the transformer, check for any component that may be short-circuited (fan, gas valve) that is increasing the consumption.

  • 04

    The remote control or the display indicates that there is no communication with the boiler, even though the main switch is turned on.

    Cause: Without the transformer power, the PCB does not start and cannot communicate with the control.

    First, check that the main switch and the network fuse of the boiler are in good condition before considering the transformer as faulty.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
70-80Safety function due to ignition failure (flame not detected).The TIG 35 HP ignition transformer does not deliver high voltage to the electrode and there is no spark, causing the boiler to enter ignition lockout. Check that the primary receives ~230 V during the attempt and that there is no spark/HT output; if there is voltage in the primary and no spark, the transformer is faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux Ignition Transformer Datasheet 61002105-20

Catalogue reference
61002105-20
Brand
Chaffoteaux
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer (label)
ITW
Component code
BW12026-00
Supply voltage
220-240 Vac 50-60 Hz
Power
3 VA
Maximum temperature
+90°C
Date code
DATE3501B
Batch
LOT61743
Frequently Asked Questions

Frequently asked questions about the ignition transformer 61002105-20

What voltage does the transformer of the Chaffoteaux Calydra 28 FF need?
220-240 Vac at 50-60 Hz, according to the label.
What is the power of the transformer ITW BW12026-00?
3 VA, according to the label.
When should the transformer of the Chaffoteaux Calydra 28 FF be replaced?
When does it stop transforming the supply voltage correctly?

Spare parts related to Chaffoteaux Calydra

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
ITW BW12026-00 Transformer For Chaffoteaux Calydra 28 FF