Saunier Duval Combitek F 23 E Ignition Transformer Ref. 05111000
Ignition transformer for Saunier Duval boilers Combitek, Thelia, Thema, and ThemaPlus F/C 23E. Article code Art.Nr. 07000068, model code ZAG 2 XV 01, power supply 220-240V 50-60Hz, 2.5VA, up to +85°C. It is replaced when the boiler does not ignite due to a lack of spark at the ignition electrode.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05111000
Ignition transformer with reference 05111000. Ten verified compatibilities: Thema C 23 E and Thema F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thema C 23 E | Thema | Contrasted |
| Saunier Duval Thema F 23 E | Thema | Contrasted |
| Saunier Duval Thema C 23 AS E | Thema | Contrasted |
| Saunier Duval Thema F 23 AS E | Thema | Contrasted |
| Saunier Duval Themaplus F 23 E | Themaplus | Contrasted |
| Saunier Duval Themaplus C 23 E | Themaplus | Contrasted |
| Saunier Duval Combitek F 23 E | Combitek | Contrasted |
| Saunier Duval Isofast C 28 E NOx | Isofast | Contrasted |
| Saunier Duval Thelia 23 E | Thelia | Contrasted |
| Saunier Duval Themis 23 E | Themis | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05111000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05111000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer 05111000 resolves.
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no clicking sound from the spark.
Cause: The transformer is not sending current, so the electrode is not generating a spark and the gas is not igniting.
Listen to the startup with the cover on; the sound of the spark should be audible, even if it's low.
- 02
The burner tries to ignite and immediately goes out.
Cause: A weak spark can ignite the gas briefly, but it does not keep the flame long enough for the control board to confirm it.
Measure the gas pressure and check that the gas valve opens correctly before assuming that the problem is only with the transformer.
- 03
The boiler locks out due to ignition failure after two or three attempts.
Cause: If the electrode does not receive enough current from the transformer, the control unit does not detect the flame and shuts down operation for safety.
Check that the ignition electrode is not broken, dirty, or improperly positioned before replacing the transformer.
- 04
The ignition fault occurs in the same way with each attempt.
Cause: Unlike a gas fault, which can be erratic, a damaged transformer usually fails consistently.
Note if the behavior is always the same; if so, it is an indication in favor of the transformer compared to other more variable causes.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.28 | Ignition failure at startup: the boiler attempts to ignite but does not detect a flame after the ignition sequence. | The transformer generates the high voltage for the spark; if its winding fails, there is no arc and the burner does not ignite despite the gas arriving. Check that there is NO spark, measure the primary and secondary windings with a multimeter, and also inspect the high voltage cable, the connector, and the electrodes. |
| F.29 | Repeated failed ignitions: the flame does not establish stably after several attempts. | A faulty or poorly connected transformer gives a weak or intermittent spark and causes ignition faults leading to lockout. Measure the windings, ensure the connections, and check the ionisation electrode and the high-voltage cable. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval Ignition Transformer Datasheet 05111000
- Catalogue reference
- 05111000
- Brand
- Saunier Duval
- Type of part
- Transformers
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- item code (Art.Nr.)
- 07000068
- model code
- ZAG 2 XV 01
- variant
- 10 Hz
- voltage
- 220-240 V
- network frequency
- 50-60 Hz
- power
- 2.5 VA
- maximum temperature
- +85 °C
- CE code
- CE-0085AU0189
- connector marking
- ANSTOSS