Myrra Ignition Transformer Saunier Duval Thema C 23 E Ref. 57275
RefurbishedSaunier DuvalTransformersMyrra

Myrra Ignition Transformer Saunier Duval Thema C 23 E Ref. 57275

Stock · 5 units

Myrra ignition transformer, code 23592-B, for Saunier Duval boilers Thema C 23 E, Thema F 23 E, Combitek F 23 E, and Themaplus F 23 E. It provides the 24V/30VA voltage that powers the burner's ignition electrode. It is replaced when the boiler does not ignite or does not spark despite the rest of the circuit being correct.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 57275

Ignition transformer with reference 57275. Two confirmed compatibilities: Thema C23E and Combitek F23E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Thema C23EThemaContrasted
Saunier Duval Combitek F23ECombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 57275 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 57275. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 57275 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or tries to ignite several times before locking out.

    Cause: The transformer does not deliver the necessary current for the electrode to generate the spark.

    Check the ignition electrode: dirt or incorrect spacing with the ground can cause the same fault as a defective transformer.

  • 02

    The spark appears weak, intermittent, or does not appear at the electrode.

    Cause: A transformer that degrades loses power and the spark stops being constant.

    Check the wiring between the transformer and the electrode, looking for cuts, burns, or poorly fitted connectors.

  • 03

    The display shows a lock due to flame or ignition failure when trying to start.

    Cause: Without a spark at the electrode, the control board does not detect ignition and cuts the cycle for safety.

    Before changing the transformer, confirm that the gas valve opens correctly to rule out that the fault is in the gas supply and not in the ignition.

  • 04

    The ignition works some days and fails on others, without a clear pattern.

    Cause: Moisture or condensation near the transformer can cause intermittent current leaks in the winding.

    Check for any moisture or condensation accumulated in the area of the transformer and the ignition wiring before considering it faulty.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.28Ignition fault of the burnerThe burner does not ignite after five attempts, indicating a problem in the ignition process. Check the gas supply and the condition of the ignition. If the transformer is not receiving power or is damaged, it may be the cause of this fault.
F.29Ignition fault of the burnerLike fault code F.28, the burner does not ignite after five attempts. Make sure that gas is reaching properly and that there are no obstructions. If the transformer is faulty, it may be the reason for this issue.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval 57275 Ignition Transformer Datasheet

Catalogue reference
57275
Brand
Saunier Duval
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Myrra
Code
23592-B
Primary voltage
230V
Secondary voltage
24V
Power
30VA
Frequency
50/60Hz
Fuse
T 200mA
Thermal class
ta 65/B
Additional code
107042/D
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the ignition transformer 57275

Does the Myrra transformer Ref. 57275 work for the Saunier Duval Thema F 23 E?
Yes, it is compatible with Thema C 23 E, Thema F 23 E, Combitek F 23 E, and Themaplus F 23 E.
Who manufactures the ignition transformer for the Thema C 23 E?
Myrra, according to the label, with the code 23592-B.
What fault does the Myrra 23592-B transformer resolve in the Thema C 23 E?
It is replaced when the boiler does not ignite or does not produce a spark despite the rest of the circuit being correct, because it provides the voltage that powers the ignition electrode.
What output voltage does the Myrra transformer of the Combitek F 23 E provide?
24V / 30VA on the secondary, according to the label.
What fuse does the Myrra Ref. 57275 transformer use?
T 200mA, according to the label.