Vaillant VMW 24/282-5 R1 transformer
RefurbishedVaillantTransformers

Vaillant VMW 24/282-5 R1 transformer

Stock · 1 unit

The Vaillant VMW 24/282-5 R1 transformer is a device that generates the spark needed to ignite the burner of the boiler. When this part fails, the boiler cannot start, resulting in failed ignition attempts, which can lead to fault codes F.28 or F.29. This transformer is compatible with models from the Turbo Tec, Atmo Tec, and VC ranges of Vaillant, among others. It needs to be replaced when the boiler has starting issues or extinguishes the flame during operation.

VAT included

Compatibility

Vaillant boilers compatible with reference 287450

Ignition transformer with reference 287450. 12 verified compatibilities: VMW ES 242/3 and VMW 242-3.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW ES 242/3Vaillant Turbo Tec / Turbo Pro (VMW)Contrasted
Vaillant VMW 242-3Vaillant Turbo Tec / Turbo Pro (VMW)Contrasted
Vaillant VMW 242-5Vaillant Turbo Tec / Turbo Pro (VMW)Contrasted
Vaillant VMW 240-5Vaillant Turbo Tec / Turbo Pro (VMW)Contrasted
Vaillant VMW 282-5Vaillant Turbo Tec / Turbo Pro (VMW)Contrasted
Vaillant VM 242-5Vaillant Atmo Tec / VM (heating only)Contrasted
Vaillant VM 282-5Vaillant Atmo Tec / VM (heating only)Contrasted
Vaillant VC 242 EVaillant VC / VCM (combi-compact)Contrasted
Vaillant VCM 242 EVaillant VC / VCM (combi-compact)Contrasted
Vaillant VCM 282 EVaillant VC / VCM (combi-compact)Contrasted
Vaillant VMI 280-7Vaillant VMIContrasted
Vaillant VMI 282-7Vaillant VMIContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 287450 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 287450. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 287450 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not respond to anything, neither to the remote control nor to the buttons on the panel.

    Cause: There is no power in the secondary, so the control board does not receive power to start up.

    Measure the voltage at the secondary faston with the multimeter before replacing the part; if there is no reading, the transformer may be damaged.

  • 02

    The protective fuse blows repeatedly shortly after being replaced.

    Cause: A short circuit in a component connected to the secondary (fan, gas valve, relay) is drawing more current than it should.

    Disconnect the components of the secondary one by one and check if the fuse holds before blaming the transformer.

  • 03

    There is a strange buzzing noise in the electrical panel, louder than usual.

    Cause: The core may be saturated or the winding may have a partial short circuit, causing vibrations and heating.

    Turn off the power and touch the transformer; if it is hot or smells burnt, it is an indication of a fault.

  • 04

    The boiler has been experiencing intermittent electronic faults that do not always occur in the same way.

    Cause: An unstable voltage in the secondary due to a damaged winding causes inconsistent faults.

    Note the conditions under which the fault occurs (cold, hot, many hours of use) and measure the secondary voltage at those times if you can reproduce it.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.28Fault during start-up: the boiler fails to ignite the burner in the start-up phase.The ignition transformer is part of the ignition system (transformer + cable + electrode); if the transformer fails, it does not generate the high voltage for the spark, and the boiler aborts the start-up without detecting a flame. Verify: measure the transformer's output voltage to the electrode and check for a spark at each start-up; if there is no spark and the wiring/electrode are fine, the transformer is the cause.
F.29The flame goes out during operation and re-ignition attempts fail.The Vaillant service documentation explicitly lists "the ignition transformer has a spark fault" as the cause of F.29: if the transformer does not reignite after a flame failure, the lockout is triggered. Verify: check the spark generation of the transformer during ignition retries and rule out poor grounding, gas pressure, and condensate pipe before.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 287450 ignition transformer datasheet

Catalogue reference
287450
Brand
Vaillant
Type of part
Transformers
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Primary voltage
230 V
Secondary voltage
17 V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the ignition transformer 287450

Is this transformer suitable for the Vaillant VMW 24/282-5 R1?
Yes, it is compatible with the VMW 24/282-5 R1.
Which models are compatible with the Vaillant transformer TCVR1?
It is compatible with the following models: VMW ES 242/3, VMW 242-3, VMW 242-5, VMW 240-5, VMW 282-5, VM 242-5, VM 282-5, VC 242 E, VCM 242 E, VCM 282 E, VMI 280-7, and VMI 282-7. In total, there are 12 confirmed models.
What voltages does the Vaillant transformer TCVR1 have?
According to the label, it has 230 V on the primary side and 17 V on the secondary side.
What fault codes are documented for this transformer?
The documented fault codes are F.28 and F.29.
Is this transformer suitable for Vaillant heating boilers?
Yes, it is suitable for the Vaillant Atmo Tec / VM range (heating only), including the VM 242-5 and VM 282-5 models.

Spare parts related to Vaillant Turbo Tec / Turbo Pro (VMW)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant VMW 24/282-5 R1 transformer