Saunier Duval Themaplus F23 E Ignition Transformer PCB - Ref. 57275 (356081200)
Ignition PCB for Saunier Duval Themaplus F23 E boiler, with codes 356081200 and 109042/B printed. It features an SMD transformer from manufacturer TDK and the Saunier Duval brand printed on the circuit itself. Includes connectors CN1, CN7, CN11, CN13, P2, and P3. It is replaced when the boiler does not ignite or the burner fails to start.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 57275
Ignition transformer with reference 57275. Two confirmed compatibilities: Thema C23E and Combitek F23E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thema C23E | Thema | Contrasted |
| Saunier Duval Combitek F23E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 57275 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 57275. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer 57275 resolves.
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no sound of any spark attempt in the burner.
Cause: The ignition transformer is not working, so the necessary spark is not being generated.
Check that the connectors on the PCB (CN1, CN7, CN11, CN13) are properly seated and free of oxidation.
- 02
The ignition fails sometimes, and other times the boiler starts without any issues.
Cause: The transformer is starting to fail and is not delivering spark consistently.
Check the ignition electrode: if it is dirty or misaligned, it may appear to be a fault with the transformer.
- 03
There is no spark at the electrode even though the boiler is trying to ignite.
Cause: The transformer may be damaged and is not sending high voltage to the electrode.
Check the wiring between the PCB and the electrode, and make sure there is no moisture in the area of the transformer.
- 04
The ignition is intermittent: sometimes it lights on the first try and other times it requires several attempts.
Cause: The transformer is degraded and the spark is not consistent in each cycle.
Before replacing the part, clean and readjust the electrode gap, which is often the cause of irregular ignition.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.28 | Ignition fault of the burner | The burner does not ignite after five attempts, indicating a problem in the ignition process. This may be due to a fault in the ignition transformer. Check the gas supply and the condition of the transformer. |
| F.29 | Ignition fault of the burner | The burner does not ignite after five attempts, indicating a problem in the ignition process. A fault in the ignition transformer could be the cause. Make sure that the gas is reaching properly and that the transformer is functioning. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval 57275 Ignition Transformer Datasheet
- Catalogue reference
- 57275
- Brand
- Saunier Duval
- Type of part
- Transformers
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB reference
- ST1389 0A0 C029
- Date code
- 9904
- Silkscreen code
- 356081200
- Silkscreen code
- 109042/B
- Connector voltage
- 200 V
- Brand printed on the PCB
- Saunier Duval
- SMD transformer component
- TDK
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Combitek F23E Manual (PDF)Document © Saunier Duval, provided as a technical reference.