Saunier Duval Themaplus F23 E Ignition Transformer PCB - Ref. 57275 (356081200)

Saunier Duval Themaplus F23 E Ignition Transformer PCB - Ref. 57275 (356081200)

Stock · 4 units

Ignition PCB for Saunier Duval Themaplus F23 E boiler, with codes 356081200 and 109042/B printed. It features an SMD transformer from manufacturer TDK and the Saunier Duval brand printed on the circuit itself. Includes connectors CN1, CN7, CN11, CN13, P2, and P3. It is replaced when the boiler does not ignite or the burner fails to start.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 57275

Ignition transformer with reference 57275. Two confirmed compatibilities: Thema C23E and Combitek F23E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Thema C23EThemaContrasted
Saunier Duval Combitek F23ECombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 57275 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 57275. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 57275 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no sound of any spark attempt in the burner.

    Cause: The ignition transformer is not working, so the necessary spark is not being generated.

    Check that the connectors on the PCB (CN1, CN7, CN11, CN13) are properly seated and free of oxidation.

  • 02

    The ignition fails sometimes, and other times the boiler starts without any issues.

    Cause: The transformer is starting to fail and is not delivering spark consistently.

    Check the ignition electrode: if it is dirty or misaligned, it may appear to be a fault with the transformer.

  • 03

    There is no spark at the electrode even though the boiler is trying to ignite.

    Cause: The transformer may be damaged and is not sending high voltage to the electrode.

    Check the wiring between the PCB and the electrode, and make sure there is no moisture in the area of the transformer.

  • 04

    The ignition is intermittent: sometimes it lights on the first try and other times it requires several attempts.

    Cause: The transformer is degraded and the spark is not consistent in each cycle.

    Before replacing the part, clean and readjust the electrode gap, which is often the cause of irregular ignition.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.28Ignition fault of the burnerThe burner does not ignite after five attempts, indicating a problem in the ignition process. This may be due to a fault in the ignition transformer. Check the gas supply and the condition of the transformer.
F.29Ignition fault of the burnerThe burner does not ignite after five attempts, indicating a problem in the ignition process. A fault in the ignition transformer could be the cause. Make sure that the gas is reaching properly and that the transformer is functioning.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval 57275 Ignition Transformer Datasheet

Catalogue reference
57275
Brand
Saunier Duval
Type of part
Transformers
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB reference
ST1389 0A0 C029
Date code
9904
Silkscreen code
356081200
Silkscreen code
109042/B
Connector voltage
200 V
Brand printed on the PCB
Saunier Duval
SMD transformer component
TDK
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the ignition transformer 57275

Does this ignition PCB work for the Saunier Duval Themaplus F23 E?
Yes, it is compatible with the Themaplus F 23 E, as well as the Combitek F 23 E and the Thema C 23 E.
What fault indicates that this PCB needs to be replaced in the Themaplus F23 E?
That the boiler does not ignite or the burner fails to start.
What connectors does the ignition PCB of the Saunier Duval F23 E have?
CN1, CN7, CN11, CN13, P2 and P3, according to the silkscreen.

Spare parts related to Saunier Duval Thema

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Themaplus F23 E Ignition Transformer PCB - Ref. 57275 (356081200)