Ignition Transformer ERA Junkers Bosch ZWA 24-1 AM 31 - Ref. 8747201294
RefurbishedJunkersTransformersERA

Ignition Transformer ERA Junkers Bosch ZWA 24-1 AM 31 - Ref. 8747201294

Stock · 4 units

ERA ignition transformer, model Typ EI 60/25,5, for Junkers and Bosch boilers from the Eurosmart ZWA/ZSA 24 range. Operates with 230 V on the primary and delivers 25 V / 26 VA on the secondary. OEM reference 8747201294, confirmed on the label and by external sources. Generates the ignition spark for the burner; it is replaced when the boiler fails to ignite or locks out due to ignition failure.

VAT included

Compatibility

Junkers boilers compatible with reference 8747201294

Ignition transformer with reference 8747201294. Three confirmed compatibilities: ZWA 24-1 AM 23 and ZWA 24-1AM23.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWA 24-1 AM 23Junkers Eurosmart ZWA 24Contrasted
Junkers ZWA 24-1AM23Junkers Eurosmart ZWA 24Contrasted
Junkers ZWA 24-1 A 23Junkers Eurosmart ZWA 24Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8747201294 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8747201294. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 8747201294 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The ignition attempts can be heard, but the burner does not ignite.

    Cause: The transformer does not generate the necessary high voltage spark even though the control board commands the ignition.

    Make sure the ignition electrode is clean and at the correct distance before replacing the transformer.

  • 02

    The boiler locks out due to an ignition fault and requests a reset.

    Cause: If a flame is not detected within the safety time after the ignition attempt, the PCB cuts off the gas and locks the unit.

    Check the wiring between the transformer and the electrode: a loose wire causes the same blockage even if the transformer is not broken.

  • 03

    There is no measurable voltage at the output of the transformer even though it is receiving power.

    Cause: The secondary winding of the transformer is cut or degraded and does not deliver the ignition high voltage.

    With a multimeter, measure that 230V is reaching the primary before concluding that the fault is in the transformer.

  • 04

    The ignition is weak and unstable, with the flame taking time to stabilize.

    Cause: Insufficient spark voltage in the transformer makes it difficult for the gas and air mixture to ignite cleanly.

    Check that the electrode is not carbonized or with a rounded tip, as this can also cause weak ignitions without the transformer failing.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Junkers 8747201294 ignition transformer datasheet

Catalogue reference
8747201294
Brand
Junkers
Type of part
Transformers
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type
Typ EI 60/25.5
Manufacturer's internal code
BV 060-0316.0
Primary voltage and frequency
230 V, 50/60 Hz (Pin 5-7)
Secondary voltage and power
25 V, 26 VA (Pin 10-12)
Maximum ambient temperature
60 °C
OEM reference
8747201294
Frequently Asked Questions

Frequently asked questions about the ignition transformer 8747201294

Does this ignition transformer ERA work for the Junkers ZWA 24-1 AM 23 boiler?
Yes, this transformer is compatible with the Junkers ZWA 24-1 AM 23 model.
Is it an original Junkers or Bosch part, or from another manufacturer?
The transformer is manufactured by ERA, model Typ EI 60/25.5; it is used as a spare part in Junkers and Bosch boilers.
What reference should be requested for this ignition transformer?
The reference to request is 8747201294, confirmed both on the part's label and by external sources.
What fault indicates that this ignition transformer needs to be replaced?
It is replaced when the boiler does not ignite or locks out due to an ignition fault, as it generates the ignition spark for the burner.
What output voltage does this transformer ERA Typ EI 60/25.5 provide?
It offers 230 V on the primary side and 25 V / 26 VA on the secondary side.
How many models are compatible with this ignition transformer?
This transformer is compatible with a total of 3 confirmed models: ZWA 24-1 AM 23, ZWA 24-1AM23, and ZWA 24-1 A 23.

Spare parts related to Junkers Junkers Eurosmart ZWA 24

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model