Ignition Transformer ZIG 2 - Saunier Duval Isofast Condens F30 B 1 - Ref. A000035144
Ignition transformer code ZIG 2, SD variant, for Saunier Duval boilers. It generates the high voltage spark that ignites the burner. Operates at 300 V / 20 kHz with a maximum temperature of 80°C, and its connector has 4 pins: positive, flame, ignition, and ground. The manufacturer of the part is not confirmed in this datasheet. It is replaced when the boiler does not ignite or the spark fails.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference A000035144
Ignition transformer with reference A000035144. 11 verified compatibilities: Isofast Condens F 30 E and Isofast Condens F 35 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Isofast Condens F 30 E | Saunier Duval | Contrasted |
| Saunier Duval Isofast Condens F 35 E | Saunier Duval | Contrasted |
| Saunier Duval Isofast 21 Condens F 25 | Saunier Duval | Contrasted |
| Saunier Duval Isofast 21 Condens F 30 B | Saunier Duval | Contrasted |
| Saunier Duval Thema Condens F 18 E | Saunier Duval | Contrasted |
| Saunier Duval Thema Condens F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thema Condens F 30 E | Saunier Duval | Contrasted |
| Saunier Duval Themaplus Condens F 30 E | Saunier Duval | Contrasted |
| Saunier Duval Isotwin Condens F 35 E | Saunier Duval | Contrasted |
| Saunier Duval Enviroplus F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Enviroplus F 28 E | Saunier Duval | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. A000035144 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference A000035144. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer A000035144 resolves.
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and no spark is observed at the electrode when trying to start.
Cause: The transformer does not generate the high voltage necessary for the spark to jump at the electrode.
Check that the 4-pin connector is properly seated and free of oxidation before considering the transformer faulty.
- 02
The ignition is intermittent: sometimes it lights and sometimes it doesn't.
Cause: The transformer delivers voltage irregularly, which is common when the internal winding degrades due to heat.
Check that the electrode does not have a worn tip and that the spark gap is not too wide, as this can cause the same symptom without the transformer failing.
- 03
The spark can be heard, but it sounds weak or different from usual.
Cause: An insufficient output voltage in the transformer produces a weak spark that does not always ignite the mixture.
Check that the ceramic insulator of the electrode is not cracked; a ground leak there also weakens the spark.
- 04
The boiler starts up well when cold but stops doing so after a while of operation.
Cause: The transformer can fail due to temperature when it heats up, as it operates close to its thermal limit of 80°C.
Check that the combustion chamber ventilation is not obstructed, as accumulated heat accelerates this type of fault.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.28 | Start-up fault: ignition failed | If the ignition transformer is faulty, no spark is generated at the electrodes and the burner does not ignite. Check for the presence of a spark during start-up and measure the power supply to the transformer and high voltage output/insulation along with wiring and grounding. |
| F.29 | Operating fault: failed ignition attempts | A faulty or intermittent ignition transformer causes spark failures during retries and the boiler locks out with F.29. Check for sustained spark in each attempt, continuity/output of the transformer, and the condition of ignition and ground cables. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval Ignition Transformer Datasheet A000035144
- Catalogue reference
- A000035144
- Brand
- Saunier Duval
- Type of part
- Transformers
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Model code
- ZIG 2
- Variant
- SD
- Voltage / Frequency
- 300 V / 20 kHz
- Maximum temperature
- 80 °C
- Pin assignment of the connector
- 1 (+), 2 (flame), 3 (ignition), 4 (- / ground)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Isofast Condens F 30 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.