3-Way Valve Saunier Duval Thelia 23 - Ref. 05134000
3-way valve, the component that directs water between the heating circuit and the domestic hot water circuit according to the boiler's demand. The body is embossed with the code 00200028-05, alongside a 2-pin gold electrical connector. It is compatible with Thelia, Themis, Combitek, and the SD 220/228/235 series, among other models. It is replaced when there is a failure in switching between DHW and heating or if there are internal leaks.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05134000
3-way valve with reference 05134000. 17 verified compatibilities: Thelia 14/23 and Thelia 23 CE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thelia 14/23 | Thelia | Contrasted |
| Saunier Duval Thelia 23 CE | Thelia | Contrasted |
| Saunier Duval Thelia 23E CE | Thelia | Contrasted |
| Saunier Duval Thelia 623 | Thelia | Contrasted |
| Saunier Duval Thelia 623 CE | Thelia | Contrasted |
| Saunier Duval Thelia 623E CE | Thelia | Contrasted |
| Saunier Duval Themis 214/23 | Themis | Contrasted |
| Saunier Duval Themis 223 | Themis | Contrasted |
| Saunier Duval Themis 23 | Themis | Contrasted |
| Saunier Duval Themis 23E CE | Themis | Contrasted |
| Saunier Duval SD 228 C | SD | Contrasted |
| Saunier Duval SD 235 C | SD | Contrasted |
| Saunier Duval SD 235 mE | SD | Contrasted |
| Saunier Duval SD220F | SD | Contrasted |
| Saunier Duval Combitek C 23 E | Combitek | Contrasted |
| Saunier Duval Combitek F 23 E | Combitek | Contrasted |
| Saunier Duval CL2335 | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05134000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05134000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 05134000 resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler takes a long time to provide hot water at the tap, although the heating works fine.
Cause: The valve does not fully switch to the domestic hot water circuit and the water continues to circulate through the heating system.
Check that the gas valve motor turns and fits properly when opening a hot water tap; if it doesn't move, first check the 2-pin connector.
- 02
The radiators go cold just when a hot water tap is opened.
Cause: The valve gets stuck in the hot water position and does not return to heating when the tap is closed.
If the stem is accessible, move the valve by hand to rule out that it is stuck due to scale before replacing it.
- 03
A clicking or snapping sound is heard in the area of the valve every time you request domestic hot water.
Cause: The internal mechanism changes abruptly when the spring or the motor no longer dampens the movement properly.
Locate the exact source of the noise with the boiler running; if it comes from the pump or a nearby bleed valve, it is not the gas valve.
- 04
Water is appearing at the base of the boiler, near the hydraulic block.
Cause: The internal seal of the valve is lost, and water leaks between the two circuits or to the outside of the body.
Dry the area and check after one heating cycle and one domestic hot water cycle to confirm that the leak is coming from the gas valve and not from a nearby joint.
- 05
The domestic hot water comes out lukewarm, neither cold nor really hot.
Cause: The valve gets stuck halfway between the two positions and mixes both circuits.
First, rule out the heat exchanger or the temperature sensor; if the problem only appears when switching modes, it points to the valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05134000 three-way valve.
- Catalogue reference
- 05134000
- Brand
- Saunier Duval
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- code engraved on the body
- 00200028-05
- electrical connector
- 2 pins, gold
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thelia 14/23 Manual (PDF)Document © Saunier Duval, provided as a technical reference.