3-Way Valve 24V Saunier Duval Thema F 23 E Ref. 05740400

3-Way Valve 24V Saunier Duval Thema F 23 E Ref. 05740400

45 €VAT includedOUT OF STOCK

If you notice that there is hot water but no heating, or that both circuits are mixing, you may need the 3-Way Valve 24V Saunier Duval Thema F 23 E. This valve is responsible for directing water between the heating circuit and the domestic hot water circuit. When it fails, you may receive fault codes such as F.318, F.326, or F.081. It is compatible with boilers from the Thema, Themaplus, and Combitek ranges, among others. It is recommended to replace it when these malfunction symptoms occur.

Compatibility

Saunier Duval boilers compatible with reference 05740400

Three-way valve with reference 05740400. Seven confirmed compatibilities: Thema F 23 E and Thema C 23 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Thema F 23 EThemaContrasted
Saunier Duval Thema C 23 EThemaContrasted
Saunier Duval Thema 23ThemaContrasted
Saunier Duval Themaplus C 23 EThemaplusContrasted
Saunier Duval Themaplus F 23 EThemaplusContrasted
Saunier Duval Combitek C 23CombitekContrasted
Saunier Duval Combitek F 23CombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05740400 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05740400. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the 3-way valve 05740400 resolves.

The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no hot water or heating, and the problem switches circuits without a clear pattern.

    Cause: The 24V actuator is not receiving the command or does not have enough power to fully move the damper.

    Check if the actuator makes noise or moves when requesting hot water; if it doesn't move, suspect the wiring or power supply before the valve.

  • 02

    The motor can be heard trying to turn, but the boiler does not switch circuits.

    Cause: The internal gear of the actuator is worn out or the shutter is stuck and the motor cannot overcome the resistance.

    Listen to see if the noise of effort occurs in all cycles or only sometimes, to differentiate between a temporary blockage and advanced wear.

  • 03

    The valve gets stuck halfway, without completing the circuit change.

    Cause: The actuator loses its position reference and stops before completing its travel.

    Turn off and then restore power to the boiler to check if the gas valve resets and completes its cycle before replacing it.

  • 04

    The noise when switching circuits is much louder than before.

    Cause: The mechanical stop of the actuator is worn out and hits at the end of each stroke.

    Compare the noise over several consecutive cycles; if it increases over time, it indicates wear of the actuator and not a one-time fault.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.318The 3-way motorised valve is not moving.The 3-way valve (actuator or gears) is blocked or without power, so it does not switch between DHW/heating; check by activating the service test and checking voltage/continuity at the motor connector.
F.326The hydraulic test of the sensor and the actuator has determined that at least two hydraulic components are not functioning.If the 3-way valve is blocked or disconnected, the hydraulic test detects multiple faults; check the valve movement from the test menu and inspect the connector/wiring harness or replace the assembly if it does not operate.
F.081The boost has failed.The brand documents the 3-way valve as a possible cause when it is defective or blocked; confirm by actuating it in service test and, if it does not switch or consumes without turning, replace the valve/motor and check the wiring.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05740400 three-way valve.

Catalogue reference
05740400
Brand
Saunier Duval
Type of part
3-way valves
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
24 V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the 3-way valve 05740400

What voltage does the actuator of this valve Ref. 05740400 operate at?
At 24 V, according to the label on the part.
Is this gas valve compatible with the Saunier Duval Themaplus C 23 E?
Yes, the Themaplus C 23 E is on the list of boilers compatible with this 24 V gas valve.
What fault in a Combitek C 23 requires changing this gas valve?
It is replaced if it does not switch properly and leaves the boiler without domestic hot water or heating.

Spare parts related to Saunier Duval Thema

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
3-Way Valve 24V Saunier Duval Thema F 23 E Ref. 05740400