FIME Extractor GR02848 Biasi Garda / Riva Ref. BI1366102
The FIME GR02848 extractor is a flue fan designed for Biasi Garda and Riva boilers. Its function is to expel combustion gases and generate the necessary draft for the boiler to start. When it fails, the boiler may not ignite or may lock out due to a fault in the flue gas evacuation, displaying the fault code 05E: Flue pressure switch anomaly. This extractor is also compatible with models from the Minox and Micon ranges, among others. It should be replaced when these malfunction symptoms are detected.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI1366102
Extractor with reference BI1366102. Three confirmed compatibilities: Minox Eco 28E and Minox 3 32 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Minox Eco 28E | Minox | Contrasted |
| Biasi Minox 3 32 E | Minox | Contrasted |
| Biasi Micon 24E | Micon | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI1366102 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1366102. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor BI1366102 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and a fault related to the flue or extraction appears on the screen.
Cause: The extractor does not reach the necessary revolutions and the pressure switch does not allow ignition.
Check that the flue outlet is not obstructed or blocked from the outside before replacing the fan.
- 02
The extractor is making noise, vibrating, or sounding different than it did before.
Cause: The bearing or the turbine of the extractor wears out with use and loses its original balance.
Listen if the noise changes when touching the boiler casing: it may be transmitted vibration and not from the extractor itself.
- 03
The extractor stops halfway through the ignition cycle and the boiler locks out.
Cause: A fault in the motor or its power supply causes it to lose speed and the system to shut down for safety.
Check for any dust or lint buildup in the turbine, as it can sometimes prevent it from spinning even if the motor is not actually faulty.
- 04
The extractor takes longer than usual to start or struggles to gain speed.
Cause: The aging motor or one with a slightly stuck shaft requires more initial thrust to start up.
Check the mains voltage and ensure there are no power drops when starting other devices before attributing it to the extractor.
Fault codes for Biasi that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 05E | Flue pressure switch anomaly. | If the fan/extractor (Fime GR02040B, ref. BI1366102) does not start or does not generate sufficient depression, the flue pressure switch does not switch, and the PCB reports 05E; check 230 V to the fan, actual rotation, and depression/continuity in the pressure switch and venturi. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi extractor BI1366102
- Catalogue reference
- BI1366102
- Brand
- Biasi
- Type of part
- Extractor fans
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- FIME
- Model (FIME)
- GR02848
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Manual Biasi Minox 3 32 E (PDF)Document © Biasi, provided as a technical reference.