Filling Key Fagor FE-24 NOx - Ref. MU0886600
When you open the filling tap of your boiler, the Fagor FE-24 NOX filling valve - Ref. MU0886600 allows you to replenish water to the heating circuit and recover the necessary pressure. If this part fails, you will notice that you cannot refill the circuit or that it is continuously leaking water, which can cause the pressure to rise uncontrollably. This valve is compatible with boilers such as the FE-24, FE-24E, FE24, among others. It should be replaced when you notice that it is not fulfilling its filling function or is leaking.
VAT included
Consult via WhatsAppCompatible Fagor boilers
Filling key. Seven confirmed compatibilities: NOX and 1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor NOx | FE-24 | Contrasted |
| Fagor 1N | FE-24E | Contrasted |
| Fagor 1N | FE24 | Contrasted |
| Fagor FE28E1B | FE28E1B | Contrasted |
| Fagor FE28E1N | FE28E1N | Contrasted |
| Fagor FEE202B | FEE202B | Contrasted |
| Fagor FEE281B | FEE281B | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve resolves
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler pressure drops and it needs to be replenished often.
Cause: The valve does not close properly and allows water to continuously flow into the circuit.
Close the valve completely and check if the pressure gauge rises with the boiler cold and stopped for several hours; if it rises on its own, the valve is not sealing.
- 02
Water or moisture appears on the stem even when the valve is closed.
Cause: The internal seal of the stem has lost its tightness due to use.
Dry the area well and check if it becomes damp again after a while with the valve closed, without touching anything else.
- 03
It is difficult to turn it or it gets stuck halfway through the movement.
Cause: The accumulation of limescale from the mains water blocks the internal mechanism.
Try to move it gently in both directions; if it doesn't give, do not force it with tools as you may break the body.
- 04
The rubber cap is broken, cracked, or missing.
Cause: It is the part most exposed to the environment of the boiler room and degrades first.
Check if the stem underneath rotates normally before considering that the key is lost.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor filling key data sheet
- Brand
- Fagor
- Type of part
- Filling valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days