Vaillant Gas Valve VMW 242/4-5 M Ref. 0020019992
Refurbished Vaillant Gas valves

Vaillant Gas Valve VMW 242/4-5 M Ref. 0020019992

The Vaillant Gas Valve VMW 242/4-5 M, with reference 0020019992, is a component that regulates the flow of gas to the burner of the boiler. Its function is crucial, as it allows gas to reach the burner under the command of the control board. When this valve fails, the user may notice that the boiler does not ignite, experiences flame lockouts, or has modulation issues. It is compatible with several models from the Vaillant Turbotec range, such as the VM 242/4-5 and the VMW 255/4-7, among others. A technician must confirm through diagnosis whether it needs to be replaced when faults F.61, F.62, F.26, F.27, or F.28 are detected.

Type of part
Gas valves
Catalogue reference
0020019992
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Vaillant boilers compatible with reference 0020019992

Gas valve with reference 0020019992. Four confirmed compatibilities: VM 242/4-5 (VM24245) and VMW ES 242/4-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VM 242/4-5 (VM24245)Vaillant Turbotec / VM-VMW ES (LPG butane-propane)Contrasted
Vaillant VMW ES 242/4-5Vaillant Turbotec / VM-VMW ES (LPG butane-propane)Contrasted
Vaillant VM 240/3-5 (M24035)Vaillant Turbotec / VM-VMW ES (LPG butane-propane)Contrasted
Vaillant VMW 255/4-7 (VMW25547)Vaillant Turbotec / VM-VMW ES (LPG butane-propane)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020019992 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020019992. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 0020019992

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite and turns off after a few seconds, without producing a flame.

    Cause: The gas valve does not allow gas to flow to the burner or cuts it off prematurely, and the control board locks for safety.

    Measure with a multimeter if current is reaching the gas valve before considering it faulty.

  • 02

    The burner is not receiving gas even though the rest of the boiler starts up normally.

    Cause: The coil of the gas valve does not open the internal shutter.

    Make sure that the main gas shut-off valve is open and that the inlet pressure is correct before replacing the gas valve.

  • 03

    The boiler locks out indicating an electrical fault, with no current in the valve circuit.

    Cause: The coil has an open circuit and does not generate the necessary magnetic field to open.

    Measure continuity at the terminals of the coil with the multimeter; if it indicates an open circuit, confirm that it needs to be replaced.

  • 04

    The boiler turns on intermittently, sometimes it does and sometimes it doesn't.

    Cause: The valve shutter does not open or close consistently due to internal wear.

    First, check that there is no fault in the ionization or ignition electrode, as they can cause similar symptoms.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.61Fault: gas valve operationThe PCB cannot actuate the gas valve (coils short-circuited/open or harness damaged), so it does not open/close. Check continuity/insulation of coils and wiring to the valve and ensure the PCB delivers a signal according to the manual.
F.62Gas valve disconnection delayThe gas valve does not close in time or remains slightly open, and the equipment detects gas/flame after the stop command. Check the valve's tightness and closure (leak test and ionization reading) and the electrical condition of the valve/wiring.
F.26Stepper motor current of gas valve not plausibleStepper motor fault of the gas valve (disconnected, faulty, or with interrupted wiring) prevents positioning. Check connectors/harness, coil resistance of the stepper, and signal from the PCB; replace the valve if the motor does not respond.
F.27Safety shutdown: flame simulationAn internal leak in the gas valve (solenoid that does not close tightly) can allow gas to pass through and the equipment 'sees' a flame without demand. Check the tightness and closure of the solenoid with a leak test/manometer and electrical check of the valve.
F.28The appliance does not start: unsuccessful ignition attemptsIf the gas valve is faulty, improperly adjusted, or not the correct part, it does not supply gas for ignition. Check inlet pressure, valve adjustment/offset, and control from the PCB; confirm with diagnostics that the valve operates and replace/adjust if necessary.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Vaillant 0020019992

Catalogue reference
0020019992
Uniclima internal SKU
VGCVTTVMW
Brand
Vaillant
Type of part
Gas valves
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Current
1 A
Ambient temperature
-15°C to +70°C
Diameter
8 mm
Frequently Asked Questions

Frequently asked questions about the gas valve 0020019992

Does this gas valve Vaillant VMW 242/4-5 M work for my boiler Vaillant?
Yes, the valve is compatible with the model VMW 242/4-5, which is on the list of confirmed boilers.
What reference is engraved on this valve?
The gas valve Vaillant has the reference 0020019992 engraved.
What current does the gas valve Vaillant VMW 242/4-5 M operate on?
The valve operates at 1 A, according to the label.
What ambient temperature range can this gas valve withstand?
It supports temperatures from -15°C to +70°C, according to the label.
How many models are compatible with this gas valve?
This valve is compatible with a total of 4 models from the Vaillant range.
What is the product reference?
VGCVTTVMW is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model