Ecoflam Desy 24 CA CPR PCB · 65101374

VAT included In stock: last unit

Ecoflam boilers compatible with reference 65101374

  • Desy + 24 CA CPREcoflam Desy + 24
  • Desy + 24 CS CPREcoflam Desy + 24
  • TX 23 MFFIAriston (compatible range)
  • TX 23 MIAriston (compatible range)
  • EST 23 MIAriston (compatible range)
  • EST IN 23 MCSIAriston (compatible range)
  • TEC IN 23 MFFIAriston (compatible range)
  • Microgenus 23 MFFIAriston (compatible range)

Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.

How to check if Ref. 65101374 is the spare part for your boiler

  1. Read the reference on your PCB

    It must show 65 101 374 on the label or the screen print. If it is not legible, do not work it out from its shape.

  2. Find the model of your boiler

    It is on the rating plate. Look it up in the compatible list.

  3. Compare label, PCB and board version

    With the installed board, before fitting.

  4. If you are unsure, send us a photo

    For the screen print: we will confirm it with you before you buy.

Symptoms that require diagnosis on this spare part (electronic board 65101374)

The boiler does not ignite at all, and the pilot light does not illuminate

Cause
The electronic control is not receiving power or has a damaged component
What to do
Check the fuse on the PCB and verify that there is voltage at the terminal block before replacing it

Any work must be carried out by qualified professionals in gas and electricity. Repair and diagnosis

Error codes for Ecoflam that require diagnosis

Error 301: EEPROM error (internal electronic part).

Technical checks
The EEPROM memory of the main PCB is corrupted/damaged; check the 230 V power supply and 5/3.3 V voltages on the PCB and bus/display connections; if reprogramming is not possible or the fault persists, replace the PCB.

Technical sheet: electronic board Ecoflam 65101374

The Ecoflam Desy boilers, such as the Desy 24 CA CPR, use this PCB to control functions such as ignition, burner modulation, and system safety features. When the PCB fails, you may notice that the boiler does not start, locks out, or exhibits erratic behavior. Fault codes such as 301, 303, 305, 306, or 307 may also appear, related to internal issues with the electronic part. This part is compatible with models from the Ecoflam Desy 24 range, as well as some Ariston boilers. A technician must confirm through diagnosis whether it needs to be replaced when faults occur to avoid further issues.

Frequently asked questions about the spare part electronic board Ecoflam 65101374

For which models is the PCB Ref. 65101374 compatible?

It is compatible with the models from the Ecoflam Desy + 24 range: Desy + 24 CA CPR and Desy + 24 CS CPR, as well as with the models from the Ariston range: TX 23 MFFI, TX 23 MI, EST 23 MI, EST IN 23 MCSI, TEC IN 23 MFFI, and Microgenus 23 MFFI. In total, there are 8 confirmed models.

When should I replace the PCB PLEC176 in the Desy + 24 CA CPR boiler?

The technical diagnosis must confirm whether it is necessary to replace it when the electronic control of the boiler fails.

What fault codes are documented for this PCB?

The documented fault codes for the PCB Ref. 65101374 are: 301, 303, 305, 306, and 307.

Is the PCB Ref. 65101374 compatible with models from other brands?

No, this PCB is only compatible with the models specified in the compatibility table.

What should I do if my boiler shows a fault code?

If your boiler shows one of the fault codes 301, 303, 305, 306, or 307, it is advisable to check the condition of the PCB Ref. 65101374.

How do I know if this spare part (PCB) 65101374 is the right one for my Ecoflam boiler?

Look at the reference printed on the installed spare part (PCB): it should read 65 101 374. Then check the model on your boiler’s rating plate. This spare part (PCB) has eight verified compatibilities, in the families Ecoflam Desy + 24 and Ariston (gama compatible). If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.

What does it mean that this spare part (PCB) is reconditioned?

That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. As it is an electronic component prepared for a specific boiler model, returns are not accepted.

How much does shipping cost and how long does it take to arrive?

TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.

The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.

Can I return it if it turns out not to be the right spare part for me?

No. Returns are not accepted for electronic boards: each one is inspected, tested and prepared for a specific boiler model, and the law treats these products as personalised, with no right of withdrawal (article 103 c of the Real Decreto Legislativo 1/2007). Furthermore, once connected it is not possible to check whether it has suffered damage, so it cannot be bought to test whether the fault lies in the board.

If it arrives faulty or we send you a different reference from the one you ordered, we will take responsibility, and this spare part PCB has a 1-year warranty. Before you buy, send us a photo of the label on your spare part PCB via WhatsApp and we will confirm that it is the right one for you. Read the returns policy.

More spare parts for your boiler Ecoflam