Plate Heat Exchanger ALTO - Cointra Edyco ED 21 EI - Ref. 9158624
RefurbishedCointraPlate heat exchangerHIGH

Plate Heat Exchanger ALTO - Cointra Edyco ED 21 EI - Ref. 9158624

Stock · 1 unit

Plate heat exchanger for Cointra boilers Edyco ED 21 EI, Edyco ED-21, and Supra SP 21 EI. According to the label, the actual manufacturer of the component is ALTO, with the code ART.NO YYY160000811 and manufacturing date 040616. It transfers heat between the primary circuit and the domestic hot water circuit. It is replaced if it loses tightness, becomes clogged, or decreases the performance of DHW.

VAT included

Compatibility

Cointra boilers compatible with reference 9158624

Plate heat exchanger with reference 9158624. Two confirmed compatibilities: ED 21 EI and EDYCO ED-21.

Proven compatibility

Boiler modelFamilyVerification
Cointra ED 21 EICointra Edyco ED 21Contrasted
Cointra EDYCO ED-21Cointra Edyco ED 21Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 9158624 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9158624. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the heat exchanger 9158624 resolves.

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Less hot water is coming out than expected, or the water is arriving lukewarm.

    Cause: The accumulated limescale on the plates prevents heat from being transferred properly to the water.

    Check if the water in the area is hard and if the boiler has received descaling maintenance recently.

  • 02

    A water leak is observed in the area where the heat exchanger is installed.

    Cause: A joint or weld in the plate pack has lost its tightness.

    Dry the area, turn on the boiler, and locate the exact point of the leak before replacing the part.

  • 03

    The heating circuit is losing pressure without any visible leaks outside the boiler.

    Cause: An internal microcrack allows the water from the primary circuit to escape into the domestic hot water circuit.

    Fill the circuit to the appropriate pressure and check if the pressure drops again in a few days, especially after using a lot of domestic hot water.

  • 04

    Do you notice a slight whistle when you request domestic hot water?

    Cause: The accumulation of scale between the plates narrows the water passage and causes turbulence.

    Check if the noise only occurs when requesting domestic hot water and not when the heating is on, to better identify the source.

Fault codes for Cointra that this part resolves.

CodeFaultDiagnosis and solution
E80The legionella cycle is not completed and the boiler issues a warning.The legionella cycle has not been completed. This may pose a health risk. Ensure that the plate heat exchanger is in good condition and allows for the proper heating of the water.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data Cointra 9158624

Catalogue reference
9158624
Brand
Cointra
Type of part
Plate heat exchanger
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Brand of the component (label)
HIGH
MAN.NO.T
106493.1413 QL (likely batch or production marking, not commercial reference)
Manufacturing date (D/W)
040616
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the plate heat exchanger 9158624

Is this plate heat exchanger compatible with the Cointra Edyco ED 21 EI?
Yes, it is compatible with the Cointra Edyco ED 21 EI.
Can I use this heat exchanger in the Edyco ED-21?
Yes, this heat exchanger is compatible with the Edyco ED-21.
When should I replace the heat exchanger IPCED21EI?
You must change it when it loses tightness, becomes obstructed, or the performance of domestic hot water (DHW) decreases.
What fault codes are associated with this heat exchanger?
The documented fault code for this heat exchanger is E80.
How many models are compatible with this plate heat exchanger?
This heat exchanger is compatible with a total of 2 confirmed models.

Spare parts related to Cointra Cointra Edyco ED 21

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Plate Heat Exchanger ALTO - Cointra Edyco ED 21 EI - Ref. 9158624