Pressure Gauge Boiler Chaffoteaux MX2 24 FF Ref. 60000816

Pressure Gauge Boiler Chaffoteaux MX2 24 FF Ref. 60000816

If you notice that the pressure in your boiler is not displayed correctly or you experience lockouts due to a false lack of pressure, a technical diagnosis should confirm if you need the pressure gauge for the Chaffoteaux MX2 24 FF boiler Ref. 60000816. This part measures and controls the pressure of the circuit, ensuring it operates within the appropriate parameters. If it fails, the readings may be incorrect, affecting the performance of the boiler. It is compatible with models such as the MX2 24 CF, COMPY MX2 24 FF, among others. A technician should confirm through diagnosis if it needs to be replaced when you observe erratic readings or frequent lockouts.

Catalogue reference
60000816
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Chaffoteaux boilers compatible with reference 60000816

Pressure gauge with reference 60000816. 18 confirmed compatibilities: MX2 24 CF and MX2 24 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux MX2 24 CFMX2 / COMPY MX2Contrasted
Chaffoteaux MX2 24 FFMX2 / COMPY MX2Contrasted
Chaffoteaux COMPY MX2 24 CFMX2 / COMPY MX2Contrasted
Chaffoteaux COMPY MX2 24 FFMX2 / COMPY MX2Contrasted
Chaffoteaux COMPY MX2 30 FFMX2 / COMPY MX2Contrasted
Chaffoteaux MIRA 24 CFLOOKContrasted
Chaffoteaux MIRA 24 FFLOOKContrasted
Chaffoteaux MIRA 30 CFLOOKContrasted
Chaffoteaux MIRA 30 FFLOOKContrasted
Chaffoteaux MIRA COMFORT 24 FFMIRA COMFORTContrasted
Chaffoteaux MIRA COMFORT 30 FFMIRA COMFORTContrasted
Chaffoteaux MIRA GREEN 24 FFMIRA GREENContrasted
Chaffoteaux MIRA GREEN 30 FFMIRA GREENContrasted
Chaffoteaux MIRA GREEN 35 FFMIRA GREENContrasted
Chaffoteaux MIRA SYSTEM 24 FFMIRA SYSTEMContrasted
Chaffoteaux MIRA SYSTEM 30 FFMIRA SYSTEMContrasted
Chaffoteaux COMPY 24 CFCOMPYContrasted
Chaffoteaux COMPY 24 FFCOMPYContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 60000816 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60000816. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the manometer 60000816

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge does not register pressure even after filling the circuit several times.

    Cause: If the manometer is damaged, it will not show the actual pressure even if the circuit is full.

    Check if the water is coming in through the filling valve; you should notice or hear the flow, and the needle should move during the filling, not just at the end.

  • 02

    The needle stays in the red zone and does not move even when I bleed the air.

    Cause: A stuck mechanism or a broken spring can cause the needle to remain at one end instead of following the actual pressure.

    Bleed a radiator to lower the pressure and check if the needle moves; if it stays fixed, the pressure gauge is faulty.

  • 03

    There is moisture or rust at the base of the pressure gauge.

    Cause: The connection to the boiler is often a leak point due to wear and corrosion over time.

    Dry the area and check again in a few hours if humidity reappears before confirming the leak and replacing the part.

  • 04

    The dial is not clearly visible, the bezel or the glass is damaged.

    Cause: Visual wear does not mean that the measuring mechanism is failing.

    If the damage is only aesthetic and the needle moves correctly when bleeding or refilling, consider whether you really need to replace the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux pressure gauge 60000816

Catalogue reference
60000816
Uniclima internal SKU
MPCMX224FF
Brand
Chaffoteaux
Type of part
Pressure gauges & aquastats
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Reference
60000816
Pressure scale / range
0-3(+) bar, with green/red zone and red mark at 3
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure gauge 60000816

Is the pressure gauge Ref. 60000816 compatible with the Chaffoteaux MX2 24 FF boiler?
Yes, the pressure gauge Ref. 60000816 is compatible with the Chaffoteaux MX2 24 FF boiler.
Which boiler models are compatible with the pressure gauge MPCMX224FF?
The MPCMX224FF manometer is compatible with a total of 18 models, including the MX2, MIRA, MIRA COMFORT, MIRA GREEN, MIRA SYSTEM, and COMPY ranges.
What is the maximum pressure indicated by the manometer of the Chaffoteaux MX2 24 FF?
Its scale goes up to 3(+) bar, with a green/red zone and a red mark at the value of 3.
Is the reference 60000816 of this manometer confirmed?
Yes, the reference 60000816 is confirmed both on the part label and from external sources.
Is this manometer suitable for the Chaffoteaux COMPY 24 CF?
Yes, the pressure gauge is compatible with the Chaffoteaux COMPY 24 CF, as well as with other models in the COMPY range.
What fault codes does this manometer have?
There are no documented fault codes.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model