Heatline Boiler Pressure Gauge Ref. D004090673

Heatline Boiler Pressure Gauge Ref. D004090673

Stock · 1 unit

The pressure gauge of the Heatline boiler, reference D004090673, measures and controls the pressure of the circuit. If it fails, you may notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This part is compatible with models such as Capriz 25, Sargon 24, and Vizo 24, among others. It is recommended to replace it if you notice that the pressure is not displayed correctly or if the boiler has operational issues related to pressure.

VAT included

Compatibility

Airsol boilers compatible with reference D004090673

Pressure gauge with reference D004090673. 18 verified compatibilities: Capriz 25 and Capriz 25S.

Proven compatibility

Boiler modelFamilyVerification
Airsol Capriz 25Heatline CaprizContrasted
Airsol Capriz 25SHeatline CaprizContrasted
Airsol Capriz 28Heatline CaprizContrasted
Airsol Capriz C24Heatline CaprizContrasted
Airsol Sargon 20SHeatline SargonContrasted
Airsol Sargon 24Heatline SargonContrasted
Airsol Sargon 24SHeatline SargonContrasted
Airsol Sargon 30Heatline SargonContrasted
Airsol Sargon 30SHeatline SargonContrasted
Airsol Sargon 35Heatline SargonContrasted
Airsol Vizo 24Heatline VizoContrasted
Airsol Vizo Plus 24Heatline VizoContrasted
Airsol Soluxe 30Heatline SoluxeContrasted
Airsol Soluxe 35Heatline SoluxeContrasted
Airsol Compact C24Heatline CompactContrasted
Airsol Compact C28Heatline CompactContrasted
Airsol Star 24Heatline StarContrasted
Airsol Star 28Heatline StarContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. D004090673 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference D004090673. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge D004090673 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge always stays at the same reading, no matter what I do with the filling valve.

    Cause: An internal mechanism that is blocked does not respond to actual pressure changes and remains fixed on a false reading.

    Open and close the filling valve while observing if the needle moves; if it never reacts, the fault is with the pressure gauge.

  • 02

    The pressure reading doesn't match what the installer told me or what it showed before.

    Cause: With use, the mechanism loses accuracy and the reading deviates from the actual circuit pressure even though it continues to move.

    Compare the reading before and after bleeding a radiator: if the pressure change is not reflected in the needle, confirm the fault of the pressure gauge.

  • 03

    The glass or the dial is cracked, and I don't trust what it indicates.

    Cause: A bump or the passage of time can damage the casing without the measuring mechanism actually being broken.

    If only the glass is damaged and the needle moves normally when bleeding or refilling, consider if the issue is merely cosmetic before replacing the entire part.

  • 04

    The boiler gradually loses pressure, and I'm not sure if it's the pressure gauge or a real leak in the installation.

    Cause: A pressure gauge with a leak at its own connection can give the impression that the circuit is losing water when it is not.

    Mark the level on the gauge with a marker and check if it drops only when the boiler is running or also when it's cold and off; this way you can distinguish a real leak from a fault in the pressure gauge.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Airsol D004090673 pressure gauge datasheet

Catalogue reference
D004090673
Brand
Airsol
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure range
0-4 bar
Frequently Asked Questions

Frequently asked questions about the pressure gauge D004090673

Is this pressure gauge D004090673 compatible with the Heatline Capriz 25S boiler?
Yes, the Capriz 25S is on the list of boilers compatible with this part.
What symptoms indicate that I should change the pressure gauge of the Heatline Compact C24?
It should be replaced when the needle does not move, shows an incorrect pressure, or the dial is broken.
What is the maximum pressure measured by the manometer D004090673?
Its scale goes up to 4 bar, from 0 to 4 bar printed on the dial.
How many models are compatible with the pressure gauge Heatline Ref. D004090673?
This pressure gauge is compatible with a total of 18 models of Heatline boilers.
What is the reference for the pressure gauge from the brand Heatline?
The reference for the pressure gauge is MPCHKB130.
Is this manometer suitable for the Heatline Sargon range?
Yes, it is compatible with several models from the Heatline Sargon range.

Spare parts related to Airsol Heatline Sargon

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Heatline Boiler Pressure Gauge Ref. D004090673