CEME Pressure Sensor For Fagor FE 24 NOx Ref. AS0003115
CEME SpA pressure sensor, code 5240BB00, for Fagor boilers FE 24 NOX and FE20E/2. It measures the circuit pressure between 0 and 4 bar (type PE) and provides an output signal of 0.5 to 3.5 Vdc proportional to the pressure, with a power supply of 8 to 30 Vdc. It is replaced when the boiler locks due to incorrect pressure reading or fails to detect pressure.
VAT included
Consult via WhatsAppFagor boilers compatible with reference AS0003115
Pressure sensor with reference AS0003115. Two confirmed compatibilities: FE 24 NOX and FEE 24 NOX.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 24 NOx | Fagor | Contrasted |
| Fagor FEE 24 NOx | Fagor | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. AS0003115 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference AS0003115. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch AS0003115 resolves.
The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is locking out and displaying a water pressure fault.
Cause: The sensor does not send the correct signal to the PCB, which interprets that there is not enough pressure.
Check the manometer and refill the circuit if the pressure is low; if the pressure is correct and the fault persists, the problem may be the sensor.
- 02
The display indicates a pressure fault even though the pressure gauge is within its normal range.
Cause: The electronic sensor shows a reading different from the actual pressure because its output signal has deviated.
Compare the pressure on the display with that of the analog manometer of the same unit before discarding the sensor.
- 03
The boiler does not start despite there seeming to be enough water pressure.
Cause: The control unit relies on the signal from the sensor and not on what the manometer shows, so a fault in the sensor prevents the start-up.
Check the cables and the connector of the sensor for any loose or oxidized contacts that may interrupt the signal before replacing it.
- 04
The pressure reading on the display fluctuates, drops to zero, or blinks without apparent reason.
Cause: An unstable output signal from the sensor arrives irregularly at the PCB.
With the boiler on, carefully move the wiring of the sensor to see if the reading changes when you touch it; this would indicate a loose wire or connector.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F3 | Heating circuit pressure out of range (low or high). | The pressure sensor (AS0003115) may send an incorrect signal and indicate a lack/excess of pressure even if the actual pressure is correct; verify by comparing the physical pressure gauge with the display value and measuring the sensor signal (≈0.5–3.5 V) or temporarily testing/replacing the sensor. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for Fagor pressure sensor AS0003115
- Catalogue reference
- AS0003115
- Brand
- Fagor
- Type of part
- Pressure sensors
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- CEME SpA
- Code
- 5240BB00
- Pressure range
- 0-4 bar
- Type
- PE
- Output
- 0.5-3.5 Vdc
- Power Supply (IN)
- 8-30 Vdc
- Maximum pressure
- MAX 8 bar
- Printed date (possible manufacturing date)
- 23/10/12