Grundfos Circulator Pump UPS15-50 CESAO 4 - Micra 2 24 SE Boiler - Ref. 149100103
Grundfos circulating pump type UPS15-50 CESAO 4, with brand and model printed on the casing. It operates at 230V~/50Hz with three selectable speeds (25/70/100 W), IP42 protection, and a maximum pressure of 0.3 MPa. It is responsible for moving water through the heating circuit; it is replaced when circulation fails, makes noise, or leaks from the shaft.
VAT included
Consult via WhatsAppRenova boilers compatible with reference 149100103
Circulating pump with reference 149100103. Eight confirmed compatibilities: 23 SE and 24 SE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Renova 23 SE | Micra | Contrasted |
| Renova 24 SE | Micra | Contrasted |
| Renova 23 E | Micra 2 | Contrasted |
| Renova 24 SE | Micra 2 | Contrasted |
| Renova 23 E | Habitat 2 | Contrasted |
| Renova 24 SE | Habitat 2 | Contrasted |
| Renova 23 SE | Habitat Plus | Contrasted |
| Renova 23 E | Supermicra | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 149100103 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 149100103. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump 149100103 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler takes a long time to heat up or doesn't heat properly, as if it's struggling to reach the desired temperature.
Cause: If there is little circulation, the water returns lukewarm to the heat exchanger and the boiler operates more than usual.
Increase the pump to the highest speed on the selector before changing it: sometimes that's all it takes.
- 02
A buzzing or gurgling sound is heard in the pump when the boiler is turned on.
Cause: It's almost always air in the circuit, not a motor fault.
Bleed the air from the pump head and check the circuit pressure before replacing it.
- 03
The boiler locks out due to a differential pressure or circulation fault.
Cause: The differential pressure switch detects that the water is not moving and shuts off for safety.
Check that the pump is running (vibration or buzzing) and that there is no shut-off valve closed in the circuit.
- 04
The radiators are cold with the boiler on.
Cause: Without the pump's push, the water does not circulate through the heating circuit.
Bleed the radiators first: the accumulated air in them also prevents circulation even if the pump is working well.
- 05
Water leak from the pump shaft or housing.
Cause: The mechanical seal wears out over the years and starts to leak.
Tighten the screws on the body and check the flange gaskets before considering the pump broken.
Fault codes for Renova that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.23 | Safety shutdown: temperature variation too large (NTC1/NTC2). | A blocked or reduced power circulating pump prevents flow, and the flow temperature rises significantly compared to the return. Check the pump's voltage and consumption, unblock the rotor, and check the flow/return ΔT after bleeding. |
| F.24 | Safety shutdown: temperature increase too rapid. | If the pump is seized or weakened, the flow rate drops and the primary overheats very quickly. Check the power supply and rotation of the pump, actual flow rate, and perform a complete bleed of the circuit. |
| F.89 | Error: pump. | The electronics detect the pump as not/poorly connected or short-circuited. Check the pump connector and wiring, motor continuity/insulation, and ensure it receives 230 V when the PCB commands operation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Renova 149100103 circulator pump.
- Catalogue reference
- 149100103
- Brand
- Renova
- Type of part
- Pumps
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Actual manufacturer
- Grundfos (brand and logo printed on the part)
- Model / Type
- UPS15-50 CESAO 4
- Part Number (P/N)
- 59A35000
- Production Code (PC)
- 0830HR
- Nominal voltage
- 230V~
- Frequency
- 50Hz
- Condenser
- 2 µF
- Current and power speed 1
- 0.12 A / 25 W
- Current and power speed 2
- 0.32 A / 70 W
- Current and power speed 3
- 0.43 A / 100 W
- Degree of protection
- IP 42
- Insulation class
- TF 95 / Class H
- Maximum pressure
- 0.3 MPa