Biasi GME 24 Circulating Pump - Ref. BI1002101
The Manaut GME 24 circulator pump, manufactured by Salmson and with reference BI1002101, is responsible for moving water through the heating circuit. If it experiences faults, you may notice cold radiators, strange noises, overheating, or blockages due to lack of circulation. This pump is compatible with models such as GMA 24, GMA 24 P, GMA 28, GME 24, and GME 28, among others. It is advisable to replace it when these symptoms are detected to avoid more significant problems in the heating system.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI1002101
Circulating pump with reference BI1002101. Seven confirmed compatibilities: GMA 24 and GMA 24 P.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi GMA 24 | Biasi GMA | Contrasted |
| Biasi GMA 24 P | Biasi GMA | Contrasted |
| Biasi GMA 28 | Biasi GMA | Contrasted |
| Biasi GME 24 | Biasi GME | Contrasted |
| Biasi GME 28 | Biasi GME | Contrasted |
| Biasi GSA 24 | Biasi GSA/GSE | Contrasted |
| Biasi GSE 24 | Biasi GSA/GSE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. BI1002101 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1002101. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump BI1002101 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pump does not start even though the boiler requests heating.
Cause: The motor may be blocked after a period of inactivity or it is not receiving power.
Check if there is power at the pump connector and try to unlock the shaft with a screwdriver if it has a bleed screw.
- 02
Noise or vibration in the circulator while operating.
Cause: There may be air trapped in the circuit or wear on the impeller.
Bleed the air through the screw on the head before assuming that the pump is worn out.
- 03
The burner ignites but the boiler does not heat, as if the heat is not coming out.
Cause: If there is no circulation, the hot water remains in the heat exchanger and does not distribute heat throughout the system.
Check that the shut-off valves of the heating circuit are open before blaming the pump.
- 04
Water leak from the body or shaft of the pump.
Cause: The internal seal loses tightness over time and with use.
Dry the area well and check again after a while of operation: sometimes it is condensation and not a real leak.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi circulator pump BI1002101
- Catalogue reference
- BI1002101
- Brand
- Biasi
- Type of part
- Pumps
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 1~220V, 50Hz
- Condenser
- 2.6 µF - 400V
- Insulation class
- F (TFSS)
- Pressure and protection
- PN6 - IP42
- Power
- 90 W
- Current
- 0.40 A
- Salmson model
- NYE53-15-o C
- Salmson article code
- 4505721
- Secondary code
- 6-02/01-041988