Biasi GME 24 Circulating Pump - Ref. BI1002101
RefurbishedBiasiPumpsSalmson

Biasi GME 24 Circulating Pump - Ref. BI1002101

Stock · 4 units

The Manaut GME 24 circulator pump, manufactured by Salmson and with reference BI1002101, is responsible for moving water through the heating circuit. If it experiences faults, you may notice cold radiators, strange noises, overheating, or blockages due to lack of circulation. This pump is compatible with models such as GMA 24, GMA 24 P, GMA 28, GME 24, and GME 28, among others. It is advisable to replace it when these symptoms are detected to avoid more significant problems in the heating system.

VAT included

Compatibility

Biasi boilers compatible with reference BI1002101

Circulating pump with reference BI1002101. Seven confirmed compatibilities: GMA 24 and GMA 24 P.

Proven compatibility

Boiler modelFamilyVerification
Biasi GMA 24Biasi GMAContrasted
Biasi GMA 24 PBiasi GMAContrasted
Biasi GMA 28Biasi GMAContrasted
Biasi GME 24Biasi GMEContrasted
Biasi GME 28Biasi GMEContrasted
Biasi GSA 24Biasi GSA/GSEContrasted
Biasi GSE 24Biasi GSA/GSEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1002101 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1002101. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulator pump BI1002101 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pump does not start even though the boiler requests heating.

    Cause: The motor may be blocked after a period of inactivity or it is not receiving power.

    Check if there is power at the pump connector and try to unlock the shaft with a screwdriver if it has a bleed screw.

  • 02

    Noise or vibration in the circulator while operating.

    Cause: There may be air trapped in the circuit or wear on the impeller.

    Bleed the air through the screw on the head before assuming that the pump is worn out.

  • 03

    The burner ignites but the boiler does not heat, as if the heat is not coming out.

    Cause: If there is no circulation, the hot water remains in the heat exchanger and does not distribute heat throughout the system.

    Check that the shut-off valves of the heating circuit are open before blaming the pump.

  • 04

    Water leak from the body or shaft of the pump.

    Cause: The internal seal loses tightness over time and with use.

    Dry the area well and check again after a while of operation: sometimes it is condensation and not a real leak.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Biasi circulator pump BI1002101

Catalogue reference
BI1002101
Brand
Biasi
Type of part
Pumps
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Voltage
1~220V, 50Hz
Condenser
2.6 µF - 400V
Insulation class
F (TFSS)
Pressure and protection
PN6 - IP42
Power
90 W
Current
0.40 A
Salmson model
NYE53-15-o C
Salmson article code
4505721
Secondary code
6-02/01-041988
Frequently Asked Questions

Frequently asked questions about the circulator pump BI1002101

For which boiler models is the Manaut GME 24 circulator pump (Ref. BOMGME24) compatible?
It is compatible with the following models: GMA 24, GMA 24 P, GMA 28, GME 24, GME 28, GSA 24, and GSE 24.
What technical specifications does the Manaut GME 24 circulator pump have?
The Manaut GME 24 circulation pump has a voltage of 220V, a frequency of 50Hz, a power of 90W, and a current of 0.40A.
How many boiler models are compatible with the Manaut GME 24 pump?
There are a total of 7 boiler models compatible with the Manaut GME 24 pump.
What fault codes does the Manaut GME 24 circulator pump have?
There are no documented fault codes.
Where can I find the reference for the Manaut GME 24 circulation pump?
The reference for the pump is BOMGME24.