Thermowatt Ignition Transformer for Chaffoteaux TIG 35 HP CF - Cod. 380060
Ignition transformer manufactured by Thermowatt, code 380060, identified on the part's label. It generates the necessary voltage to produce the spark that ignites the boiler's burner. It is replaced when the boiler does not ignite, clicks at the electrode without a flame, or the display shows an ignition fault. Compatible with TIG 35 HP CF and other models in the range.
VAT included
Consult via WhatsAppCompatible Chaffoteaux boilers
Ignition transformer. 11 verified compatibilities: GREEN and 28 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux GREEN | ALIXIA | Contrasted |
| Chaffoteaux 28 FF | CALYDRA | Contrasted |
| Chaffoteaux 1.35 HP CF | CELTIC | Contrasted |
| Chaffoteaux CENTORA | CENTORA | Contrasted |
| Chaffoteaux HE 35 | GENUS | Contrasted |
| Chaffoteaux HE 35 | MINIMUM | Contrasted |
| Chaffoteaux NECTRA | NECTRA | Contrasted |
| Chaffoteaux DELTA 28 FF | NIAGARA | Contrasted |
| Chaffoteaux GREEN | PIGMA | Contrasted |
| Chaffoteaux GREEN SYSTEM 35 FF | TALIA | Contrasted |
| Chaffoteaux 35 HP CF | TIG | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer resolves
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, a click is heard in the burner but there is no spark or flame.
Cause: The transformer does not generate enough current for the arc to jump between the electrodes.
Check in the dark, with the boiler requesting ignition, if there is a spark at the electrode before considering the transformer faulty.
- 02
The display shows an ignition fault and the boiler locks out after several attempts.
Cause: Without a spark, the control board does not detect flame within the safety time and aborts the cycle.
Check that the electrode and the high voltage cable do not have a cracked sheath or moisture before blaming the transformer.
- 03
A crackling or strange buzzing sound is heard in the area of the transformer when starting up.
Cause: A transformer that starts to fail can produce partial discharge or internal leakage before completely stopping functioning.
Check that the distance between the electrodes is correct and that there is no soot bridging the arc.
- 04
The boiler ignites sometimes yes and sometimes no, intermittently.
Cause: A damaged coil loses power irregularly, especially with the boiler cold.
Test several consecutive starts and note if the fault depends on whether the boiler is cold or has been running for a while.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux ignition transformer datasheet
- Brand
- Chaffoteaux
- Type of part
- Transformers
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Power
- 2VA
- Frequency
- 50/60Hz
- Primary voltage
- 230V (terminals 1-3)
- Operating temperature
- ta60 C/E
- Additional code on label
- 92770