3-Way Valve Motor Laura 20/30/35 A/AF - Ref. 16506000.02 / MPMV5301 Ref. 122450340
- For 3 Roca boilers Roca Laura
- 220V-240V
- Check for: The boiler does not switch properly between heating and domestic hot water., The boiler shows an error or blockage related to the 3-way valve.
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Roca boilers compatible with reference 122450340
- Laura 20Roca Laura
- Laura 20/20Roca Laura
- Laura 20/20 FRoca Laura
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 122450340 is the spare part for your boiler
-
Read the reference on your valve
It must show 122 450 340 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (3-way valve 122450340)
The boiler does not switch properly between heating and domestic hot water.
- Cause
- The MPMV5301 motor does not move the diverter all the way in one of the two directions.
- What to do
- Check if the motor completes the travel to the end; some models have a position mark on the upper cap.
The motor of the 3-way valve makes noise or gets stuck halfway.
- Cause
- The internal gear of the motor wears out with use and loses strength to move the shaft all the way to the end.
- What to do
- Disassemble the motor and turn the shaft by hand; if it is harder than usual, confirm that the fault is in the motor and not in the valve body.
The boiler shows an error or blockage related to the 3-way valve.
- Cause
- The motor's end switch does not send the correct position signal to the PCB, which cuts off operation for safety reasons.
- What to do
- Check the motor connector and make sure the terminals are not loose or corroded before replacing the part.
The heating or domestic hot water operates intermittently, turning on and off without apparent reason.
- Cause
- The diverter does not stay fixed in the correct position and oscillates between the two circuits.
- What to do
- Check if the problem occurs consistently in the same mode (heating or domestic hot water) or in both; this helps to determine if the fault is with the motor or the valve body.
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Technical sheet: 3-way valve Roca 122450340
It is the motor/actuator that moves the 3-way valve of the Laura 20, 30, and 35 boilers (A and AF), model MPMV5301, reference 16506000.02. It operates at 220V-240V, 50Hz, with thermal class T70. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not switch properly between heating and domestic hot water, or when the valve motor is stuck or makes noise.
Spare part details
- Roca reference
- 122450340
- Supply voltage
- 220V-240V
- Frequency
- 50 Hz
- Thermal class
- T70
- Actuator model
- MPMV5301
- Manufacturer code
- 16506000.02
- Batch code
- 1005
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Manual © Roca, provided as a technical reference. Technical sheet reviewed on .
Frequently asked questions about the spare part 3-way valve Roca 122450340
Is this 3-way valve motor MPMV5301 compatible with the Laura 20 boiler?
Yes, the 3-way valve motor MPMV5301 is compatible with the Laura 20 boiler.
What voltage does the motor of the 3-way valve in the Baxi Roca Laura range operate at?
It operates at 220V-240V and 50 Hz, according to the motor label.
When is it necessary to replace the MPMV5301 motor in a Laura range boiler?
The technical diagnosis must confirm whether replacement is necessary when the boiler does not switch correctly between heating and domestic hot water, or if the valve motor is stuck or making noise.
Does the MPMV5301 motor move the entire 3-way valve or just the internal mechanism?
It is the motor/actuator, model MPMV5301, that moves the 3-way valve; it is not the complete valve.
How many models are compatible with the 3-way valve motor MPMV5301?
The motor is compatible with 3 models from the Roca Laura range: Laura 20, Laura 20/20, and Laura 20/20 F.
How do I know if this spare part (valve) 122450340 is the right one for my Roca boiler?
Look at the reference printed on the installed spare part (valve): it should read 122 450 340. Then check the model on your boiler’s rating plate. This spare part (valve) has three verified compatibilities, in the Roca Laura family. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (valve) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part valve, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.