Cointra E20L PCB
Refurbished Cointra PCBs (control boards) Crovisa

Cointra E20L PCB

The Cointra E20L PCB is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or exhibit erratic behavior. The user may notice issues such as the appearance of fault codes E00, E70, E71, or E72. This board is compatible with several models from the Cointra E20L range, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or fault codes occur.

Catalogue reference
7683
Warranty
1 year
VAT included Stock · 5 units
Compatibility

Cointra boilers compatible with reference 7683

PCB with reference 7683. Six confirmed compatibilities: E20L and E20 L.

Proven compatibility

Boiler modelFamilyVerification
Cointra E20LCointra E20LContrasted
Cointra E20 LCointra E20LContrasted
Cointra E20 L/NCointra E20LContrasted
Cointra E20LNCointra E20LContrasted
Cointra E20/20 LCointra E20LContrasted
Cointra E20/20LNCointra E20LContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 7683 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7683. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 7683

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, you can hear clicks, but the spark does not come out.

    Cause: The ignition transformer on the PCB does not generate the necessary voltage for the arc.

    With the boiler turned off and without power, check that the high voltage cable to the electrode is not loose and that the electrode is not broken before replacing the complete PCB.

  • 02

    A dry click is heard on the PCB when requesting heat, but the boiler does not respond.

    Cause: The internal relay that activates the power supply to the components is stuck or does not close the contact properly.

    Check if that click is always heard when requesting heat, because if it is never heard, the problem may be earlier, in the electrical supply.

  • 03

    The boiler turns on and off by itself repeatedly, without any apparent reason.

    Cause: A fault in the PCB causes it to lose control of the ignition cycle midway through the process.

    Note if the cut-off always occurs at the same point in the cycle, as this helps distinguish a PCB fault from a sensor fault.

  • 04

    The boiler is not receiving power, neither the clock nor the display turn on.

    Cause: The PCB does not distribute the main power to the rest of the circuit.

    Check the main fuse of the house and the fuse of the PCB before replacing it.

Fault codes Cointra that require diagnosis

CodeFaultTechnical checks
E00No communication with the displayThe boiler cannot communicate with the control panel. This may be due to a fault in the PCB. Check the connections of the board and its condition.
E70Cascade alarm (without communication with SLAVEs)A cascade alarm has been triggered, indicating that the MASTER cannot communicate with one of the SLAVES. This may affect the system's performance. Check the communication between the PCB and the SLAVES.
E71Cascade alarm (alarm on one of the SLAVES)A cascade alarm has been triggered, indicating that there is an alarm in one of the SLAVES. This may affect the operation of the system. Check the status of the PCB and the SLAVES.
E72Cascade alarm (no communication with MASTER)A cascade alarm has been triggered, indicating that a SLAVE cannot communicate with the MASTER. This may affect the system's performance. Check the communication between the PCB and the MASTER.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Cointra 7683 PCB.

Catalogue reference
7683
Uniclima internal SKU
PLTCE20L
Brand
Cointra
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Transformer manufacturer
Crovisa
Transformer code
481D030
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 7683

Is this PCB suitable for the Cointra E20L boiler?
Yes, it's the specific PCB for the Cointra E20L.
What code does the transformer on this PCB have?
481D030, engraved on the transformer casing.
What other components are mounted on the PCB besides the Crovisa transformer?
It also includes a relay, as stated on the part.

Spare parts related to Cointra Cointra E20L

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Cointra E20L PCB