Honeywell PCB Ferroli Domina Insert F24E Ref. 39811411
Control PCB manufactured by Honeywell for Ferroli Domina Insert F24E, Domina Igloo F24E, Domina Insert F30E and the Ferella Box and Ferella Free ranges, reference 39811411. It operates at 230VAC with a 3-pole connection and includes a 9V transformer. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler's control module fails.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 39811411
- Warranty
- 1 year
Ferroli boilers compatible with reference 39811411
PCB with reference 39811411. Four confirmed compatibilities: Domina Insert F24E and Domina Igloo F24E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Domina Insert F24E | Domina | Contrasted |
| Ferroli Domina Igloo F24E | Domina | Contrasted |
| Ferroli Ferella Box F30 MEL | Ferella | Contrasted |
| Ferroli Ferella Free F24 MEL | Ferella | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 39811411 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39811411. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 39811411
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite at all, there is no pilot light on.
Cause: The 9V transformer on the PCB is not supplying power to the control circuit.
Check if 230VAC power is reaching the PCB and inspect the fuse before replacing it.
- 02
An error code appears on the screen and the boiler gets locked.
Cause: The PCB detects a problem with a sensor or pressure switch and shuts down for safety.
Note the code and check the component it indicates first before replacing the PCB.
- 03
The 3-pin connector seems to be properly connected, but the boiler does not respond at all.
Cause: A fault in the control module prevents the PCB from receiving the input signals.
Check that the connector is properly fitted and free of rust before declaring the PCB faulty.
- 04
The boiler turns on and off by itself intermittently.
Cause: An internal component of the PCB loses continuity when it heats up.
Check if the cut coincides with the boiler already being hot, which indicates a thermal fault in the control module.
Ferroli fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F50 | Internal control board error | An internal error has occurred in the DBM32 control board. This may affect the operation of the boiler. It is advisable to check the control board. |
| F51 | Internal control board error | Like the F50 fault code, it indicates an internal error in the DBM32 control board. Check its status and operation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli PCB 39811411
- Catalogue reference
- 39811411
- Uniclima internal SKU
- PLFE034
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- PCB manufacturer
- Honeywell
- Supply voltage
- 230VAC, 3 Pole
- Transformer voltage
- 9V
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Domina Igloo F24E Manual (PDF) Document © Ferroli, provided as a technical reference.