Plate Heat Exchanger ALTO - Cointra Supra SP 27 EI - Ref. 9158625
Plate heat exchanger for Cointra Supra SP 27 EI boilers. According to the label, the actual manufacturer of the component is ALTO, with the code ART.NO YYY000653781 and manufacturing date 061017. It transfers heat between the primary circuit and the domestic hot water circuit. It is replaced if it loses tightness, becomes clogged, or decreases the performance of DHW.
VAT included
Consult via WhatsAppCompatible Cointra boilers
Plate heat exchanger. A proven compatibility: SP 27 EI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Cointra SP 27 EI | SUPRA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the plate heat exchanger resolves
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Less hot water is coming out than it should, or the faucet is giving lukewarm water.
Cause: The embedded limescale reduces the effective surface area for transferring heat to the domestic hot water (DHW).
Check if the water in the area is hard and if the boiler has not been descaled for a long time; with hard water, scaling is the first suspicion.
- 02
There is a drip or moisture in the area where the heat exchanger is installed.
Cause: The PCBs can lose tightness due to fatigue after many heating cycles.
Dry the area and force a domestic hot water cycle and a heating cycle separately; if the leak only appears with domestic hot water, point to the heat exchanger.
- 03
The primary circuit is losing pressure without any visible leaks outside.
Cause: An internal leak in the heat exchanger can cause the water from the primary circuit to escape without leaving a visible stain.
Record the pressure on the manometer over several days with the boiler off; if it decreases steadily, check the heat exchanger before ruling it out.
Fault codes for Cointra that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E80 | Legionella cycle not completed | The legionella cycle has not been completed. This may pose a health risk. If the cycle does not run correctly, check the heat exchanger to ensure it is not blocked. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Plate heat exchanger data sheet Cointra
- Brand
- Cointra
- Type of part
- Plate heat exchanger
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Brand of the component (label)
- HIGH
- ART.NO
- YYY000653781
- MAN.NO.T
- 109036.0094 JH (likely batch or production marking)
- Manufacturing date
- 061017
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Cointra SP 27 EI Manual (PDF)Document © Cointra, provided as a technical reference.