Pressure Sensor Saunier Duval Isofast F 28 E PSA0001 C

Pressure Sensor Saunier Duval Isofast F 28 E PSA0001 C

When the pressure sensor fails, you may experience incorrect readings and lockouts due to a false lack of pressure, which can lead to fault code 09: Water pressure detector failure. The Saunier Duval Isofast F 28 E PSA0001 C pressure sensor measures the water circuit pressure and sends the information to the control board. This part is compatible with several models of Saunier Duval boilers, such as the Isofast C 28 E, Isofast F 28 E, among others. A technician should confirm through diagnosis whether it is necessary to replace the sensor when you notice these symptoms or during preventive maintenance.

Type of part
Pressure sensors
Catalogue reference
PSN0001
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Saunier Duval boilers compatible with reference PSN0001

Pressure sensor with reference PSN0001. 24 verified compatibilities: Isofast C 28 E and Isofast C 28 E1.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Isofast C 28 ESaunier DuvalContrasted
Saunier Duval Isofast C 28 E1Saunier DuvalContrasted
Saunier Duval Isofast C 35 ESaunier DuvalContrasted
Saunier Duval Isofast F 28 ESaunier DuvalContrasted
Saunier Duval Isofast F 28 E1Saunier DuvalContrasted
Saunier Duval Isofast F 35 ESaunier DuvalContrasted
Saunier Duval Themafast C 24 ESaunier DuvalContrasted
Saunier Duval Themafast C 25 ESaunier DuvalContrasted
Saunier Duval Themafast C 28 ESaunier DuvalContrasted
Saunier Duval Themafast C 30 ESaunier DuvalContrasted
Saunier Duval Themafast F 24 ESaunier DuvalContrasted
Saunier Duval Themafast F 25 ESaunier DuvalContrasted
Saunier Duval Themafast F 30 ESaunier DuvalContrasted
Saunier Duval Isomax C 28 ESaunier DuvalContrasted
Saunier Duval Isomax F 28 ESaunier DuvalContrasted
Saunier Duval Isomax F 35 ESaunier DuvalContrasted
Saunier Duval Isotwin C 24 ESaunier DuvalContrasted
Saunier Duval Isotwin C 28 ESaunier DuvalContrasted
Saunier Duval Isotwin F 24 ESaunier DuvalContrasted
Saunier Duval ThemaClassic C 24 ESaunier DuvalContrasted
Saunier Duval ThemaClassic F 24 ESaunier DuvalContrasted
Saunier Duval ThemaClassic F 25 ESaunier DuvalContrasted
Saunier Duval Thematek C 24 ESaunier DuvalContrasted
Saunier Duval Thematek F 24 ESaunier DuvalContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. PSN0001 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference PSN0001. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch PSN0001

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display shows a pressure error or the pressure symbol is flashing, even though the boiler's manometer shows normal pressure.

    Cause: The sensor sends an electrical signal that does not correspond to the actual pressure, and the control unit interprets it as a pressure fault.

    Compare the digital reading with the mechanical manometer of the boiler before declaring the sensor faulty.

  • 02

    The boiler locks out as soon as it starts, as if it doesn't have enough pressure, even though the circuit is full.

    Cause: Without a reliable signal from the sensor, the control board does not confirm the minimum pressure and cuts off the ignition for safety.

    Bleed the air from the circuit and check for any visible leaks before replacing the sensor.

  • 03

    The pressure reading on the display remains fixed, neither increasing nor decreasing, even when water is added or removed from the circuit.

    Cause: The internal element of the sensor stops translating hydraulic pressure into an electrical signal and gets "frozen" at a value.

    Tighten the connector of the sensor and check the wiring to the PCB; a loose connection produces the same effect.

  • 04

    There is moisture, limescale buildup, or dripping in the area where the sensor is screwed in.

    Cause: The gasket or body of the sensor loses tightness with use and allows water from the primary circuit to pass through.

    Dry the area, turn on the boiler, and monitor for a few minutes to confirm that the leak is coming from there and not from a nearby fitting.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
09Water pressure sensor faultThe pressure sensor (PSN0001) is faulty, disconnected, or out of range, and the PCB is not receiving a valid pressure signal; check the wiring and measure the sensor's resistance at 0/1/3 bar according to service values to confirm.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor PSN0001

Catalogue reference
PSN0001
Uniclima internal SKU
SPSDIF28E
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Pressure range
0-4.5 bar
Power supply
5 Vdc
Electrical protection class
Class III
Pinout
1: 0V / 2: +Vcc / 3: NC / 4: OUT
Code printed on the label
PSA0001 C
Batch
105227B
Manufacturing date/week
47/99 (week/year)
Place of manufacture
Made in France
Frequently Asked Questions

Frequently asked questions about the pressure sensor PSN0001

Is this sensor compatible with the Saunier Duval Isomax F 28 E?
Yes, it is on the list of compatible models, along with Isofast C 28 E, C 28 E1, C 35 E, F 28 E, F 28 E1, and F 35 E.
What kind of electrical protection does the sensor PSA0001 C have?
Protection class III, according to the label.
What pressure does this sensor measure and what power supply does it work with?
It measures from 0 to 4.5 bar with an analog output and is powered at 5 Vdc, according to the label.

Spare parts related to Saunier Duval Saunier Duval

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Pressure Sensor Saunier Duval Isofast F 28 E PSA0001 C