Pressure Sensor Saunier Duval Isofast F 28 E PSA0001 C
When the pressure sensor fails, you may experience incorrect readings and lockouts due to a false lack of pressure, which can lead to fault code 09: Water pressure detector failure. The Saunier Duval Isofast F 28 E PSA0001 C pressure sensor measures the pressure of the water circuit and sends the information to the control board. This part is compatible with several models of Saunier Duval boilers, such as the Isofast C 28 E, Isofast F 28 E, among others. It is recommended to replace the sensor when you notice these symptoms or during preventive maintenance.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference PSN0001
Pressure sensor with reference PSN0001. 24 verified compatibilities: Isofast C 28 E and Isofast C 28 E1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Isofast C 28 E | Saunier Duval | Contrasted |
| Saunier Duval Isofast C 28 E1 | Saunier Duval | Contrasted |
| Saunier Duval Isofast C 35 E | Saunier Duval | Contrasted |
| Saunier Duval Isofast F 28 E | Saunier Duval | Contrasted |
| Saunier Duval Isofast F 28 E1 | Saunier Duval | Contrasted |
| Saunier Duval Isofast F 35 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 25 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 28 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 30 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast F 25 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast F 30 E | Saunier Duval | Contrasted |
| Saunier Duval Isomax C 28 E | Saunier Duval | Contrasted |
| Saunier Duval Isomax F 28 E | Saunier Duval | Contrasted |
| Saunier Duval Isomax F 35 E | Saunier Duval | Contrasted |
| Saunier Duval Isotwin C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Isotwin C 28 E | Saunier Duval | Contrasted |
| Saunier Duval Isotwin F 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic C 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F 25 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek F 24 E | Saunier Duval | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. PSN0001 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference PSN0001. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure sensor PSN0001 resolves.
The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The display shows a pressure error or the pressure symbol is flashing, even though the boiler's manometer shows normal pressure.
Cause: The sensor sends an electrical signal that does not correspond to the actual pressure, and the control unit interprets it as a pressure fault.
Compare the digital reading with the mechanical manometer of the boiler before declaring the sensor faulty.
- 02
The boiler locks out as soon as it starts, as if it doesn't have enough pressure, even though the circuit is full.
Cause: Without a reliable signal from the sensor, the control board does not confirm the minimum pressure and cuts off the ignition for safety.
Bleed the air from the circuit and check for any visible leaks before replacing the sensor.
- 03
The pressure reading on the display remains fixed, neither increasing nor decreasing, even when water is added or removed from the circuit.
Cause: The internal element of the sensor stops translating hydraulic pressure into an electrical signal and gets "frozen" at a value.
Tighten the connector of the sensor and check the wiring to the PCB; a loose connection produces the same effect.
- 04
There is moisture, limescale buildup, or dripping in the area where the sensor is screwed in.
Cause: The gasket or body of the sensor loses tightness with use and allows water from the primary circuit to pass through.
Dry the area, turn on the boiler, and monitor for a few minutes to confirm that the leak is coming from there and not from a nearby fitting.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 09 | Water pressure sensor fault | The pressure sensor (PSN0001) is faulty, disconnected, or out of range, and the PCB is not receiving a valid pressure signal; check the wiring and measure the sensor's resistance at 0/1/3 bar according to service values to confirm. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for Saunier Duval pressure sensor PSN0001
- Catalogue reference
- PSN0001
- Brand
- Saunier Duval
- Type of part
- Pressure sensors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure range
- 0-4.5 bar
- Power supply
- 5 Vdc
- Electrical protection class
- Class III
- Pinout
- 1: 0V / 2: +Vcc / 3: NC / 4: OUT
- Code printed on the label
- PSA0001 C
- Batch
- 105227B
- Manufacturing date/week
- 47/99 (week/year)
- Place of manufacture