Honeywell 3-Way Valve VC6612 Chaffoteaux TIG 35 HP Ref. 61008271

Honeywell 3-Way Valve VC6612 Chaffoteaux TIG 35 HP Ref. 61008271

Stock · 1 unit

Motorized actuator for a 3-way valve manufactured by Honeywell, model VC6612, identified by its own label. Power supply 200-240 VAC at 50/60 Hz, 6 VA, maneuvering time of 6 seconds, and IP40 protection. It is replaced when the valve does not switch between the heating circuit and the domestic hot water circuit or the motor does not rotate.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 61008271

Three-way valve with reference 61008271. Three confirmed compatibilities: TIG 14 HP and TIG 23 HP.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux TIG 14 HPChaffoteauxContrasted
Chaffoteaux TIG 23 HPChaffoteauxContrasted
Chaffoteaux TIG 35 HPChaffoteauxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61008271 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61008271. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the 3-way valve 61008271 resolves.

The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Hot water comes out of the tap, but the radiators do not heat up, or vice versa.

    Cause: The actuator does not fully move the valve, so it distributes the water poorly between both.

    With the boiler in the correct mode, check if the valve stem moves when the actuator is activated.

  • 02

    A constant buzzing or clicking sound is heard from the motor without the gas valve moving.

    Cause: The motor tries to move the gear but fails to do so, usually due to internal wear.

    Disconnect and reconnect the power to the actuator to see if it completes a cycle before replacing it.

  • 03

    The boiler takes a long time to switch between domestic hot water and heating, or it gets stuck in between.

    Cause: The actuator extends its operating time or stops halfway through its stroke due to an internal motor fault.

    Time a complete switching cycle; if it clearly exceeds the normal seconds, the actuator is failing.

  • 04

    One of the circuits intermittently stops receiving hot water.

    Cause: The valve gets stuck halfway and distributes the flow between both circuits instead of directing it completely to one.

    Check if the fault occurs consistently in the same mode (DHW or heating) before replacing the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Chaffoteaux 3-way valve 61008271

Catalogue reference
61008271
Brand
Chaffoteaux
Type of part
3-way valves
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Actuator manufacturer
Honeywell
Model
VC6612
Power supply
200-240 VAC 50/60 Hz
Power
6 VA
Maneuvering time
6 s
Protection
IP40
Thermal class (UL)
T65 TS110
Additional printed code
40004797-003
Body ports
A / AB / B cast in the brass body
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the 3-way valve 61008271

Who manufactures the actuator for the 3-way valve of the Chaffoteaux TIG 35 HP?
Honeywell, model VC6612, according to its own label.
What protection does the Honeywell VC6612 actuator of the TIG 23 HP have against water or dust?
IP40, according to its technical specifications.
When should the 3-way valve of a Chaffoteaux TIG 14 HP be replaced?
When the valve does not switch between the heating circuit and the domestic hot water circuit, or when the actuator motor does not rotate.
How long does it take for the VC6612 actuator of the 3-way valve to operate?
6 seconds, according to the actuator label.
Is the same Honeywell VC6612 valve suitable for the three Chaffoteaux TIG 14, 23, and 35 HP?
Yes, the three boilers - TIG 14 HP, TIG 23 HP, and TIG 35 HP - are on the list of models compatible with this part.