Honeywell 3-Way Valve VC6612 Chaffoteaux TIG 35 HP Ref. 61008271
Motorized actuator for a 3-way valve manufactured by Honeywell, model VC6612, identified by its own label. Power supply 200-240 VAC at 50/60 Hz, 6 VA, maneuvering time of 6 seconds, and IP40 protection. It is replaced when the valve does not switch between the heating circuit and the domestic hot water circuit or the motor does not rotate.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61008271
Three-way valve with reference 61008271. Three confirmed compatibilities: TIG 14 HP and TIG 23 HP.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux TIG 14 HP | Chaffoteaux | Contrasted |
| Chaffoteaux TIG 23 HP | Chaffoteaux | Contrasted |
| Chaffoteaux TIG 35 HP | Chaffoteaux | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 61008271 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61008271. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 61008271 resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Hot water comes out of the tap, but the radiators do not heat up, or vice versa.
Cause: The actuator does not fully move the valve, so it distributes the water poorly between both.
With the boiler in the correct mode, check if the valve stem moves when the actuator is activated.
- 02
A constant buzzing or clicking sound is heard from the motor without the gas valve moving.
Cause: The motor tries to move the gear but fails to do so, usually due to internal wear.
Disconnect and reconnect the power to the actuator to see if it completes a cycle before replacing it.
- 03
The boiler takes a long time to switch between domestic hot water and heating, or it gets stuck in between.
Cause: The actuator extends its operating time or stops halfway through its stroke due to an internal motor fault.
Time a complete switching cycle; if it clearly exceeds the normal seconds, the actuator is failing.
- 04
One of the circuits intermittently stops receiving hot water.
Cause: The valve gets stuck halfway and distributes the flow between both circuits instead of directing it completely to one.
Check if the fault occurs consistently in the same mode (DHW or heating) before replacing the part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 3-way valve 61008271
- Catalogue reference
- 61008271
- Brand
- Chaffoteaux
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Actuator manufacturer
- Honeywell
- Model
- VC6612
- Power supply
- 200-240 VAC 50/60 Hz
- Power
- 6 VA
- Maneuvering time
- 6 s
- Protection
- IP40
- Thermal class (UL)
- T65 TS110
- Additional printed code
- 40004797-003
- Body ports
- A / AB / B cast in the brass body
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux TIG 35 HP Manual (PDF)Document © Chaffoteaux, provided as a technical reference.