Parker Filling Solenoid Valve for Fagor FEE26TC1B Ref. N31G000M8
Filling solenoid valve manufactured by Parker (manufacturer code 161.4 CM), used as an automatic filling key in Fagor boilers FEE26TC1B, FEE-27MA/1 B, and FEE40MA1N. It regulates the flow of mains water into the circuit with a passage of 2.5 mm and operates up to 15 bar, powered at 220V/50Hz. It is replaced when the automatic filling fails or there are leaks in the body.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N31G000M8
Three-way valve with reference N31G000M8. Four confirmed compatibilities: FEE 24 TC and FEE 26 TC.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FEE 24 TC | FEE | Contrasted |
| Fagor FEE 26 TC | FEE | Contrasted |
| Fagor FEE 27 MA | FEE | Contrasted |
| Fagor FEE 35 MA | FEE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N31G000M8 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N31G000M8. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the N31G000M8 three-way valve resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler gradually loses pressure and does not refill on its own.
Cause: The fill solenoid valve does not open to allow mains water to enter the circuit.
Check that the water inlet shut-off valve is open and that there is network pressure before replacing the gas valve.
- 02
The filling doesn't stop and the pressure gauge keeps rising.
Cause: The solenoid valve does not close completely and allows water to pass continuously.
Manually close the inlet valve and check if the pressure stops rising; if so, the problem is with the valve.
- 03
Water is leaking or there is moisture in the area of the filling solenoid valve.
Cause: The body or the seals of the valve have lost their tightness.
Dry the area and check if the leak reappears with the boiler at rest, without filling in progress.
- 04
The automatic filling does not start even though the pressure is low.
Cause: The solenoid valve coil is not receiving current or is burnt out and does not open the water flow.
Check if power is reaching the coil at the moment it should activate the filling.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N31G000M8 three-way valve.
- Catalogue reference
- N31G000M8
- Brand
- Fagor
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Parker
- Model/manufacturer code
- 161.4 CM
- Pitch (pitch diameter)
- 2.5 mm
- Maximum pressure
- 15 bar
- Voltage / frequency
- 220V / 50Hz
- Regulatory marking
- CE
- The manufacturer of this solenoid valve is Parker; Fagor is the brand of the compatible boiler, not the one who manufactures the part.