Flow Detector for Boiler FE24NOX / FE24TC / FEE26TC Ref. 4 521 549
Flow detector (flow switch) for the domestic hot water circuit. It detects the opening of a tap and notifies the PCB to ignite the burner and produce DHW. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not provide hot water despite having gas and pressure, or when the supply is intermittent. Compatible with FE24NOX-1B/-1N, FE24TC1N, FEE26TC1B, and 1FEE26TC1B.
- Type of part
- Flow detectors
- Status
- Refurbished
- Catalogue reference
- AS0003113
- Warranty
- 1 year
Fagor boilers compatible with reference AS0003113
Flow meter with reference AS0003113. Five confirmed compatibilities: FE 24 NOX and FE 24 NOX-1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 24 NOx | Fagor FE/FEE NOX-TC (24/26) | Contrasted |
| Fagor FE 24 NOx-1 | Fagor FE/FEE NOX-TC (24/26) | Contrasted |
| Fagor FE 24 TC (FE24TC1N) | Fagor FE/FEE NOX-TC (24/26) | Contrasted |
| Fagor FE 26 TC (FEE26TC1B / 1FEE26TC1B) | Fagor FE/FEE NOX-TC (24/26) | Contrasted |
| Fagor FEE 24 TC | Fagor FE/FEE NOX-TC (24/26) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. AS0003113 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference AS0003113. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the flow meter AS0003113
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no domestic hot water even though the boiler has enough gas and pressure.
Cause: The flow detector does not send the signal to the PCB when the tap is opened, so the burner never ignites.
Open and close the hot water tap several times and listen for any clicks or vibrations in the area of the sensor.
- 02
The burner does not start when a tap is opened, but the heating works normally.
Cause: This component only operates in the domestic hot water circuit, so its fault affects only that function without impacting the heating.
Make sure that the problem only occurs when requesting hot water and not in heating, to identify the fault in this part.
- 03
The hot water comes out in bursts, cuts off, and returns for no apparent reason.
Cause: The detector does not maintain a stable signal if the flow is just at the activation limit or if its mechanism is dirty.
Check the pressure of the installation and the water inlet filter before replacing the sensor.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Fagor Flow Meter AS0003113
- Catalogue reference
- AS0003113
- Uniclima internal SKU
- DCFFE24N
- Brand
- Fagor
- Type of part
- Flow detectors
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Code engraved on the part
- 4 521 549
- Mold marking
- L L