Caleffi Flow Detector for Cointra Domitop F 24 E Boiler
RefurbishedCointraFlow DetectorsCaleffi

Caleffi Flow Detector for Cointra Domitop F 24 E Boiler

Stock · 1 unit

The Caleffi flow detector for the Cointra Domitop F 24 E boiler is responsible for detecting the flow of water when a tap is opened, thus activating the ignition for the production of domestic hot water. If this part fails, you will notice that hot water does not come out even with the tap open. This detector is compatible with several boilers, including models such as the Domitop DGT C24E and the Domina F 24 E, among others. It is recommended to replace it when the mentioned symptoms occur, thus ensuring the supply of hot water.

VAT included

Compatibility

Cointra boilers compatible with reference 39830570

Flow meter with reference 39830570. 11 verified compatibilities: Domitop F 24 E and Domitop DGT C24E.

Proven compatibility

Boiler modelFamilyVerification
Cointra Domitop F 24 ECointra Domitop / Domitop DGT (= Ferroli Domitop)Contrasted
Cointra Domitop DGT C24ECointra Domitop / Domitop DGT (= Ferroli Domitop)Contrasted
Cointra Domitop DGT C30ECointra Domitop / Domitop DGT (= Ferroli Domitop)Contrasted
Cointra Domitop DGT F30ECointra Domitop / Domitop DGT (= Ferroli Domitop)Contrasted
Cointra Domina F 24 EFerroli DominaContrasted
Cointra Domina C30 EFerroli DominaContrasted
Cointra Domina F30 EFerroli DominaContrasted
Cointra Domina Igloo F 24 EFerroli DominaContrasted
Cointra New Elite C30Ferroli New EliteContrasted
Cointra New Elite F24Ferroli New EliteContrasted
Cointra New Elite F30Ferroli New EliteContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 39830570 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 39830570. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 39830570 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner even though water is circulating through the circuit.

    Cause: The detector is not closing the contact that alerts the PCB that there is flow, so the control unit does not authorize the ignition.

    Make sure that the detector is installed with the flow arrow in the correct direction of the water.

  • 02

    The boiler shuts down suddenly while running, as if it loses water all of a sudden.

    Cause: An intermittent flow reading causes the PCB to believe that the water has stopped circulating and cuts off for safety.

    Check for any dirt or limescale buildup on the internal paddle of the sensor before replacing it.

  • 03

    A warning for lack of water or flow is triggered even though the circuit is full and without leaks.

    Cause: The flow detector is the one that informs the PCB of the actual circulation, and if it fails, it simulates a lack of water that does not exist.

    Check that the circulation pump is running and pushing water before blaming the flow sensor.

  • 04

    The domestic hot water takes a long time to come out or doesn't come out properly, even though the tap is fully open.

    Cause: In some installations, this same sensor also indicates the flow of water to activate the production of domestic hot water.

    Check the mains pressure and the water inlet filter before declaring the detector faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Flow meter data sheet Cointra 39830570

Catalogue reference
39830570
Brand
Cointra
Type of part
Flow Detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer engraved on the part
CALEFFI
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter 39830570

Is this Caleffi flow detector suitable for a Cointra Domina F 24 E?
Yes, it is compatible with Cointra Domina F 24 E, as well as with other models from the Cointra Domitop, Ferroli Domina, and Ferroli New Elite ranges.
Who manufactures this flow detector, Cointra or Caleffi?
Caleffi. The name is engraved on the brass body of the part, next to an arrow indicating the direction of flow.
What fault of the Cointra Domitop F 24 E does this flow detector solve?
It is replaced when the boiler does not detect water circulation and therefore does not ignite, or when it turns off with the circuit already running.
How many models are compatible with this Caleffi flow detector?
This flow detector is compatible with a total of 11 models.
What is the reference for this flow detector?
The reference for this flow detector is CCCDF24E.
Are there documented fault codes for this product?
No, there are no documented fault codes for this product.

Spare parts related to Cointra Cointra Domitop / Domitop DGT (= Ferroli Domitop)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Caleffi Flow Detector for Cointra Domitop F 24 E Boiler