Gas Extractor GR00180 for Basic 23 MFFI Boiler and Compatible Models
The gas extractor GR00180 is a component from the brand Ariston designed for the Basic 23 MFFI boiler and compatible models. Its function is to evacuate combustion gases and ensure the necessary draft for the boiler to start. If it fails, the user will notice that the boiler does not ignite or gets locked due to issues with smoke evacuation, and errors such as A 41 or E 23 may appear. This extractor is installed in boilers from the Basic, Genus, and Meta ranges, among others. It should be replaced when starting failures or errors related to the fan occur.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 569431
Extractor with reference 569431. Five confirmed compatibilities: BASIC 23 MFFI and GENUS 23 BFFI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston BASIC 23 MFFI | BASIC | Contrasted |
| Ariston GENUS 23 BFFI | GENUS | Contrasted |
| Ariston GENUS ESTERNA 23 MFFI | GENUS | Contrasted |
| Ariston META 23 MSFI | GOAL | Contrasted |
| Ariston META 20 MFFI | GOAL | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 569431 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 569431. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor 569431 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The extractor does not start or has difficulty starting, with a buzzing sound but not spinning.
Cause: The motor may be seized after prolonged use or a period of inactivity, which is typical at the end of summer.
With the boiler unplugged, turn the fan by hand to check for stiffness or unusual friction.
- 02
Abnormal noise or vibration while the extractor is operating.
Cause: It is usually due to an unbalanced impeller caused by dirt or worn bearings.
Check if the impeller has soot or dust buildup and if the extractor is properly anchored to the boiler, without loose screws.
- 03
The boiler is locking out due to a combustion flue gas extraction fault.
Cause: If the extractor does not reach the required air flow, the safety system prevents the gas from being opened.
Check that the flue duct is not blocked by nests, ice, or dirt before replacing the fan.
- 04
The boiler ignites but turns off after a few seconds.
Cause: It is the typical signal that the extractor does not maintain sufficient rotation for the flue gas check system to give the green light.
Listen to see if the extractor keeps spinning just when the boiler turns off: if it stops too early, the fault clearly points to it.
Fault codes for Ariston that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A 41 | Fan error (flue gas extractor fault). | If the extractor/fan does not start or its tachometer/Hall does not deliver pulses, the PCB detects a fan fault. Check 230 V to the motor and rpm/tach signal at the connector; if there is no rotation or no pulses, the extractor is the cause. |
| E 23 | Fan speed too low. | Worn or blocked extractor rotates below the threshold and the PCB detects it as low speed. Check that the fan reaches nominal rpm (Hall pulses) and that there are no frictions; if it does not increase rpm, replace the extractor. |
| 6 01 | Flue gas expulsion fault (obstruction or fan fault). | If the extractor does not move flow or does not reach speed, the flue gas evacuation fails and the boiler locks with 6 01. Check the fan rotation and the closure of the flue gas pressure switch; if the fan does not start or does not provide flow, it is the cause. |
| 6 04 | Insufficient fan speed. | The extractor rotates below the target value (worn winding, bearings, dirt) and the electronics detect it as insufficient speed. Measure power supply and Hall signal; if the fan does not reach the specified rpm, replace it. |
| 6 12 | Incorrect fan speed measurement (fan fault/signal). | Tachometer/Hall fault of the fan or unstable rotation causes invalid rpm reading and lockout. Check Hall pulses at the connector and rpm stability; if there is no signal or it fluctuates, the fan is the cause. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ariston extractor 569431
- Catalogue reference
- 569431
- Brand
- Ariston
- Type of part
- Extractors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer code (MOD.)
- GR00180