SIT Spark Ignition Train for Fagor Boilers FE24TC, FE26TC, FEE24TC, FEE26TC and Others
Spark train manufactured by SIT, installed in Fagor boilers from the FE/FEE range (FE18TC1N, FE24NOX, FE24TC, FE26TC, FEE24NOX, FEE24TC, FEE26TC). It operates at 230V, 50/60Hz, according to the label. It is the ignition assembly of the burner; it should be checked when the boiler does not ignite or the electrode does not generate a spark. Replacement requires a technical diagnosis.
- Type of part
- Gas burners
- Status
- Refurbished
- internal SKU
- TCFE24EN
- Warranty
- 1 year
Compatible Fagor boilers
Burner. Seven confirmed compatibilities: FE18TC1N and FE24NOX.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE18TC1N | FE18TC1N | Contrasted |
| Fagor FE24NOX | FE24NOX | Contrasted |
| Fagor FE24TC | FE24TC | Contrasted |
| Fagor FE26TC | FE26TC | Contrasted |
| Fagor FEE24NOX | FEE24NOX | Contrasted |
| Fagor FEE24TC | FEE24TC | Contrasted |
| Fagor FEE26TC | FEE26TC | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the burner
The burner performs the combustion of gas. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and you do not see a spark at the electrode.
Cause: The spark train does not generate the electric arc necessary to ignite the gas.
Check if there is a spark when requesting ignition; if you see or hear nothing, the fault is with the spark train.
- 02
Several clicks are heard in succession without the boiler starting.
Cause: The spark is intermittent or too weak to consistently ignite the burner.
Check that the electrode is not rusty or dirty with soot before replacing the entire assembly.
- 03
The boiler locks out due to a flame failure after attempting to ignite.
Cause: Without a reliable spark, the flame detector does not receive a signal and the control unit locks the equipment for safety.
Check the electrical connection of the spark train and ensure that the high voltage cable is properly seated.
- 04
The electrode sparks but does not ignite the gas from the burner.
Cause: The spark may be weak or poorly positioned relative to the burner, even if the electrode is functioning.
Check the distance and alignment of the electrode with the burner before replacing the spark train.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor burner datasheet
- Uniclima internal SKU
- TCFE24EN
- Brand
- Fagor
- Type of part
- Gas burners
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- manufacturer
- SIT
- voltage
- 230 V
- frequency
- 50/60 Hz