SIT Spark Ignition Train for Fagor Boilers FE24TC, FE26TC, FEE24TC, FEE26TC and Others
RefurbishedFagorGas burnersSIT

SIT Spark Ignition Train for Fagor Boilers FE24TC, FE26TC, FEE24TC, FEE26TC and Others

Stock · 4 units

Spark train manufactured by SIT, installed in Fagor boilers from the FE/FEE range (FE18TC1N, FE24NOX, FE24TC, FE26TC, FEE24NOX, FEE24TC, FEE26TC). It operates at 230V, 50/60Hz, according to the label. It is the burner ignition assembly; it is replaced when the boiler does not ignite or the electrode does not generate a spark.

VAT included

Compatibility

Compatible Fagor boilers

Burner. Seven confirmed compatibilities: FE18TC1N and FE24NOX.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE18TC1NFE18TC1NContrasted
Fagor FE24NOXFE24NOXContrasted
Fagor FE24TCFE24TCContrasted
Fagor FE26TCFE26TCContrasted
Fagor FEE24NOXFEE24NOXContrasted
Fagor FEE24TCFEE24TCContrasted
Fagor FEE26TCFEE26TCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the burner resolves

The burner performs the combustion of gas. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and you do not see a spark at the electrode.

    Cause: The spark train does not generate the electric arc necessary to ignite the gas.

    Check if there is a spark when requesting ignition; if you see or hear nothing, the fault is with the spark train.

  • 02

    Several clicks are heard in succession without the boiler starting.

    Cause: The spark is intermittent or too weak to consistently ignite the burner.

    Check that the electrode is not rusty or dirty with soot before replacing the entire assembly.

  • 03

    The boiler locks out due to a flame failure after attempting to ignite.

    Cause: Without a reliable spark, the flame detector does not receive a signal and the control unit locks the equipment for safety.

    Check the electrical connection of the spark train and ensure that the high voltage cable is properly seated.

  • 04

    The electrode sparks but does not ignite the gas from the burner.

    Cause: The spark may be weak or poorly positioned relative to the burner, even if the electrode is functioning.

    Check the distance and alignment of the electrode with the burner before replacing the spark train.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor burner datasheet

Brand
Fagor
Type of part
Gas burners
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

manufacturer
SIT
voltage
230 V
frequency
50/60 Hz
Frequently Asked Questions

Frequently asked questions about the burner

Who manufactures the spark train for the Fagor FE24TC?
SIT, according to the label on the part.
Is this spark generator suitable for the Fagor FEE26TC?
Yes, the FEE26TC is on the list of compatible boilers, along with FE18TC1N, FE24NOX, FE24TC, FE26TC, FEE24NOX, and FEE24TC.
When should this spark train be replaced in a Fagor FE26TC?
When the boiler does not ignite or the electrode does not generate a spark.
What voltage does the spark train of the Fagor FEE24TC operate at?
230V, 50/60Hz.

Spare parts related to Fagor FE18TC1N

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
SIT Spark Ignition Train for Fagor Boilers FE24TC, FE26TC, FEE24TC, FEE26TC and Others