Saunier Duval Thema F 23 E Deprimogen Valve Ref. 05234300

Saunier Duval Thema F 23 E Deprimogen Valve Ref. 05234300

The depressurization valve regulates the pressure in the boiler, ensuring proper system operation. This component from Saunier Duval, with reference 05234300, may experience faults that manifest as unstable pressure or an inability to heat the water. It is installed in several boilers, including the Thema F 23 E, as well as others like the Combitek C 23 and the Thelia 23 E. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms of abnormal pressure are detected or when the boiler is not functioning properly.

Type of part
Gas valves
Catalogue reference
05234300
Warranty
1 year
VAT includedStock · 7 units
Compatibility

Saunier Duval boilers compatible with reference 05234300

Gas valve with reference 05234300. 12 verified compatibilities: C 23 and F 23 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 23CombitekContrasted
Saunier Duval F 23 ECombitekContrasted
Saunier Duval 235 CSDContrasted
Saunier Duval 23TheliaContrasted
Saunier Duval 23 ETheliaContrasted
Saunier Duval 623TheliaContrasted
Saunier Duval C 23ThemaContrasted
Saunier Duval C 23 EThemaContrasted
Saunier Duval F 23 EThemaContrasted
Saunier Duval C 23 EThemaplusContrasted
Saunier Duval F 23 EThemaplusContrasted
Saunier Duval 223ThemisContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 05234300 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05234300. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 05234300

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The flame rises and falls on its own, the boiler modulates irregularly without the tap being touched.

    Cause: The internal mechanism of the pressure-reducing valve is not responding correctly to the fan's depression.

    Check that the silicone tube carrying the pressure from the fan to the gas valve is not cracked, bent, or disconnected.

  • 02

    The boiler does not ignite and gets locked out during the attempt, although the fan is operating normally.

    Cause: The micro switch of the gas valve does not send the ignition permission signal to the PCB.

    Check that the fan starts and runs steadily before suspecting the gas valve.

  • 03

    A whistling or vibrating sound can be noticed in the burner area when the boiler is modulating.

    Cause: The stem or diaphragm of the valve is stuck or dirty and does not slide properly.

    Visually check that there is no corrosion or accumulated dirt in the mechanism before replacing the complete part.

  • 04

    The flame seems to 'breathe', growing and decreasing continuously on its own even though the heating demand is constant.

    Cause: An internal leak in the diaphragm of the gas valve alters the correct ratio between air and gas.

    Check if the fault occurs the same way at different power levels of the boiler, to rule out the electrode or the PCB before considering this part as good.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Saunier Duval 05234300

Catalogue reference
05234300
Uniclima internal SKU
TVITF23E
Brand
Saunier Duval
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Voltage
24V
Micro switch marking
T85
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve 05234300

Is this depressurization valve suitable for the Saunier Duval Thema F 23 E?
Yes, it is the depressurization valve of the Thema F 23 E, and it is also compatible with other models from the Thema, Thelia, Combitek, Themaplus, and Themis 223 series that are listed in the compatible boilers list.
Is this valve compatible with the Saunier Duval Thelia 23?
Yes, the Thelia 23 is on the list of compatible boilers for this gas valve.
What voltage does this pressure-reducing valve have?
24V, according to the label marking.

Spare parts related to Saunier Duval Thelia

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Thema F 23 E Deprimogen Valve Ref. 05234300