Saunier Duval Thema F 23 E Deprimogen Valve Ref. 05234300
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Saunier Duval boilers compatible with reference 05234300
- F 23 EThema
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 05234300 is the spare part for your boiler
-
Read the reference on your valve
It must show 05 234 300 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (gas valve 05234300)
The flame rises and falls on its own, the boiler modulates irregularly without the tap being touched
- Cause
- The internal mechanism of the pressure-reducing valve is not responding correctly to the fan's depression
- What to do
- Check that the silicone tube carrying the pressure from the fan to the gas valve is not cracked, bent, or disconnected
The flame seems to 'breathe', growing and decreasing continuously on its own even though the heating demand is constant
- Cause
- An internal leak in the diaphragm of the gas valve alters the correct ratio between air and gas
- What to do
- Check if the fault occurs the same way at different power levels of the boiler, to rule out the electrode or the PCB before considering this part as good
The boiler does not ignite and gets locked out during the attempt, although the fan is operating normally
- Cause
- The micro switch of the gas valve does not send the ignition permission signal to the PCB
- What to do
- Check that the fan starts and runs steadily before suspecting the gas valve
A whistling or vibrating sound can be noticed in the burner area when the boiler is modulating
- Cause
- The stem or diaphragm of the valve is stuck or dirty and does not slide properly
- What to do
- Visually check that there is no corrosion or accumulated dirt in the mechanism before replacing the complete part
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Technical sheet: gas valve Saunier Duval 05234300
The depressurization valve regulates the pressure in the boiler, ensuring proper system operation. This component from Saunier Duval, with reference 05234300, may experience faults that manifest as unstable pressure or an inability to heat the water. It is installed in several boilers, including the Thema F 23 E, as well as others like the Combitek C 23 and the Thelia 23 E. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms of abnormal pressure are detected or when the boiler is not functioning properly.
Spare part details
- Saunier Duval reference
- 05234300
- Voltage
- 24V
- Micro switch marking
- T85
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Manual © Saunier Duval, provided as a technical reference. Technical sheet reviewed on .
Frequently asked questions about the spare part gas valve Saunier Duval 05234300
Is this depressurization valve suitable for the Saunier Duval Thema F 23 E?
Yes, it is the depressurization valve of the Thema F 23 E, and it is also compatible with other models from the Thema, Thelia, Combitek, Themaplus, and Themis 223 series that are listed in the compatible boilers list.
Is this valve compatible with the Saunier Duval Thelia 23?
Yes, the Thelia 23 is on the list of compatible boilers for this gas valve.
What voltage does this pressure-reducing valve have?
24V, according to the label marking.
How do I know if this spare part (valve) 05234300 is the right one for my Saunier Duval boiler?
Look at the reference printed on the installed spare part (valve): it should read 05 234 300. Then check the model on your boiler’s rating plate. This spare part (valve) has one verified compatibility, in the Thema family. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (valve) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part valve, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.