Baxi Roca Laura 20/20F LCD Display PCB
The Baxi Roca Laura 20/20F LCD display board is a control PCB that manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically, displaying fault code 24. This part is compatible with several models in the Roca Laura 20 range, including the Laura 20 S/P, Laura 20 F, and Laura 20/20 T, among others. It should be replaced when these issues or communication errors in the system occur.
Baxi Roca boilers compatible with reference 122420030
PCB with reference 122420030. Seven confirmed compatibilities: Laura 20 S/P (GN/GP) and Laura 20 F (GN/GP).
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Laura 20 S/P (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20 F (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20/20 S/P (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20/20 F (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20/20 T (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20 A (GN/GP) | Baxi Roca Laura 20 | Contrasted |
| Baxi Roca Laura 20 AF (GN/GP) | Baxi Roca Laura 20 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 122420030 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122420030. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 122420030 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The screen does not turn on and nothing is visible on the control panel.
Cause: The F3 fuse on the display PCB may be blown, preventing the LCD from receiving power even though the boiler is operating.
Check the F3 fuse (2A) visually or with a multimeter; it is a common fault and cheaper to fix.
- 02
The buttons on the display do not respond when pressed.
Cause: The push buttons are soldered to the PCB; a poor connection or a break in them prevents adjusting the temperature from the panel.
Check if there is any reaction when pressing, even if it's minimal, and verify that the yellow/black jumper wire is properly connected.
- 03
The boiler is functioning normally, but no information is visible on the display.
Cause: The display board only shows information, so the boiler can continue operating with its main PCB even if it is damaged.
Check that the water comes out hot and that the burner ignites correctly; if everything works except the display, the problem is with this display PCB.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 24 | Communication fault between microcontrollers or PCB error. | It is the only fault code in the Laura 20/20 (F) range where the brand/SAT directly attributes the fault to the PCB (internal communication failure between microprocessors or PCB defect). Verify: check stable power supply and connections of the PCB connector; if after reset the 24 persists with correct voltage, the main PCB (ref. 122420030) is the cause and must be replaced. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca 122420030 PCB.
- Catalogue reference
- 122420030
- Brand
- Baxi Roca
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Fuse F3
- 2A
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Laura 20/20 F (GN/GP) Manual (PDF)Document © Baxi Roca, provided as a technical reference.