Wilo Circulating Pump for Biasi Garda/Parva/Riva HE Boilers Ref. BI1911103
RefurbishedBiasiPumpsWilo

Wilo Circulating Pump for Biasi Garda/Parva/Riva HE Boilers Ref. BI1911103

Stock · 1 unit

The Wilo Circulating Pump for Biasi Garda/Parva/Riva HE boilers, with reference BI1911103, is responsible for moving water through the heating circuit. If it fails, you will notice cold radiators, unusual noises, or overheating due to lack of circulation. This pump is compatible with models such as Garda M110B.32SM/E, Parva HE M96.24SM/P, Riva Compact HE M96.28SM/C, among others. It should be replaced when a circulation fault occurs, identified by fault codes E04 or E14.

VAT included

Compatibility

Biasi boilers compatible with reference BI1911103

Circulating pump with reference BI1911103. Nine confirmed compatibilities: Garda M110B.32SM/E and Parva HE M96.24SM/P.

Proven compatibility

Boiler modelFamilyVerification
Biasi Garda M110B.32SM/EBiasi Garda HEContrasted
Biasi Parva HE M96.24SM/PBiasi Parva HEContrasted
Biasi Parva HE M96.28SM/PBiasi Parva HEContrasted
Biasi Parva HE M96.32SM/PBiasi Parva HEContrasted
Biasi Riva Compact HE M96.24SM/CBiasi Riva Compact HEContrasted
Biasi Riva Compact HE M96.28SM/CBiasi Riva Compact HEContrasted
Biasi Riva Compact HE M96.32SM/CBiasi Riva Compact HEContrasted
Biasi Riva Advance HE M110B.24SM/CBiasi Riva Advance HEContrasted
Biasi Riva Advance HE M110B.32SM/CBiasi Riva Advance HEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1911103 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1911103. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump BI1911103 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler heats the domestic hot water well, but the heating takes a long time or does not heat.

    Cause: If the circulator is running weakly, it may provide enough flow for domestic hot water, but not for the heating circuit.

    Check if the noise of the pump changes (more high-pitched or intermittent) when switching from domestic hot water to heating.

  • 02

    The radiators are cold with the boiler on and the thermostat calling for heat.

    Cause: If there is no circulation, the hot water does not flow from the boiler to the system.

    Open the manual bleed valve of a nearby radiator to rule out that the problem is air in the circuit before checking the pump.

  • 03

    There is a vibration or rattling noise in the area of the pump, especially when starting up.

    Cause: The rotor may have scale buildup after the summer without use, which causes a forced and noisy start.

    If the boiler has not been used for heating for months, try several consecutive starts: sometimes the impeller frees itself.

  • 04

    The pump does not start and the boiler ends up locking out due to lack of circulation.

    Cause: A seized shaft prevents the motor from turning even though it receives power correctly.

    With the boiler turned off, try to manually unlock the shaft using the front screw before replacing the pump.

Fault codes for Biasi that this part resolves.

CodeFaultDiagnosis and solution
E04Pump circulation fault or insufficient system pressure.A seized, air-locked, or stalled circulating pump does not move the primary, the control detects a lack of flow and triggers E04. Check by initiating demand and measuring if the pump receives 230 V and rotates, bleed the pump's air vent, and confirm correct pressure in the circuit (>1–1.5 bar).
E14Circulation fault due to temperature gradient (>2 K/s) / possible pump fault.If the pump is blocked or weak, the flow rises very quickly and the control detects an abnormal gradient, generating E14. Check ΔT flow-return and ramp-up, bleed air, measure pump consumption/speed, and confirm it moves sufficient flow.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the circulator pump Biasi BI1911103

Catalogue reference
BI1911103
Brand
Biasi
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the circulator pump BI1911103

Is this Wilo BI1911103 circulation pump compatible with the Biasi Garda M110B.32SM/E?
Yes, this model is on the list of compatible boilers.
Can I use the Wilo BI1911103 pump in the Biasi Parva HE M96.24SM/P?
Yes, the Biasi Parva HE M96.24SM/P is one of the compatible models.
Does the Wilo BI1911103 pump work for the Biasi Riva Compact HE M96.28SM/C?
Yes, this model is also on the compatibility list.
How many boiler models are compatible with the Wilo BI1911103 pump?
A total of 9 models are compatible with this pump.
What fault codes are documented for the Wilo BI1911103 pump?
The documented fault codes are E04 and E14.
What is the reference for the Wilo circulator pump for Biasi boilers?
The reference for the pump is MBCMX24CE.

Spare parts related to Biasi Parva HE

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Wilo Circulating Pump for Biasi Garda/Parva/Riva HE Boilers Ref. BI1911103