Safety Valve Roca Laura Plus 28/28F Kramer Ref. 122450080
- For 19 Roca boilers Roca Laura Plus and Roca Laura 20
- PN10
- Check for: Water is continuously leaking from the valve, even though the boiler has not reached overpressure., When the pressure rises, the valve does not release water upon reaching the set point.
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Roca boilers compatible with reference 122450080
- Laura Plus 28/28 GNRoca Laura Plus
- Laura Plus 28/28 GPRoca Laura Plus
- Laura Plus 28/28F GNRoca Laura Plus
- Laura Plus 28/28F GPRoca Laura Plus
- Laura 20Roca Laura 20
- Laura 20 FRoca Laura 20
- Laura 20 ARoca Laura 20
- Laura 20 AFRoca Laura 20
- Laura 20/20Roca Laura 20
- Laura 20/20 FRoca Laura 20
- Laura 20/20 TRoca Laura 20
- Laura 30 ARoca Laura 30
- Laura 30 AFRoca Laura 30
- Laura 30/30Roca Laura 30
- Laura 30/30 FRoca Laura 30
- Laura 35 ARoca Laura 35
- Laura 35 AFRoca Laura 35
- Laura 35/35Roca Laura 35
- Laura 35/35 FRoca Laura 35
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 122450080 is the spare part for your boiler
-
Read the reference on your valve
It must show 122 450 080 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (safety valve 122450080)
Water is continuously leaking from the valve, even though the boiler has not reached overpressure.
- Cause
- The seat does not close properly, usually due to wear or a particle that prevents complete sealing.
- What to do
- Check the pressure gauge when cold; if the pressure is normal and it still drips, check the condition of the seat before considering bleeding further.
The valve jumps, expels water, and then does not close completely again.
- Cause
- After tripping, a particle may remain in the seat that prevents a clean closure.
- What to do
- Pull the lever a couple more times after it trips to try to drag out the dirt and ensure it closes properly.
There is a water leak in the quick connection area, not in the body of the gas valve.
- Cause
- This model features a quick connection that may lose tightness over time.
- What to do
- Check if the leak is coming from the connection point before replacing the entire gas valve; sometimes the issue is just the connection.
When the pressure rises, the valve does not release water upon reaching the set point.
- Cause
- The internal mechanism is jammed and does not respond even though the pressure justifies it.
- What to do
- Lift the lever manually and check that it releases water normally before replacing the part.
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Technical sheet: safety valve Roca 122450080
Kramer safety valve, set at 3 bar, with a PN10 body and 1/2" connection (male thread with quick female coupling). It releases pressure from the boiler circuit when it exceeds the set value, protecting the system from overpressure. The replacement requires first confirming the fault of the part through technical diagnosis, even when it is leaking continuously or does not close after activation.
Spare part details
- Roca reference
- 122450080
- Manufacturer
- Kramer
- Setpoint
- 3 bar
- Nominal pressure of the body (PN)
- PN10
- Connection
- 1/2" (male thread + female quick connection)
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Technical sheet reviewed on .
Frequently asked questions about the spare part safety valve Roca 122450080
Is this valve suitable for a Roca Laura Plus 28/28F?
Yes, it is on the list of compatible boilers for the part.
Who manufactures this safety valve, Kramer or Roca?
The Kramer factory, according to the label on the part itself; Roca is the brand of the boiler in which it is installed.
What pressure is the valve of the Laura Plus 28/28F set to?
At 3 bar, confirmed by the label and external sources.
What connection does this Kramer safety valve have?
1/2", with male thread and quick female coupling.
When should this safety valve be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when it is leaking continuously or does not close after the trip.
Is it also compatible with the Roca Laura 35/35?
Yes, the Laura 35/35 is on the list of compatible models.
How do I know if this spare part (valve) 122450080 is the right one for my Roca boiler?
Look at the reference printed on the installed spare part (valve): it should read 122 450 080. Then check the model on your boiler’s rating plate. This spare part (valve) has 19 verified compatibilities, in the families Roca Laura Plus, Roca Laura 20, Roca Laura 30 and Roca Laura 35. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (valve) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part valve, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.