Safety valve set at 3 bar, with DN15 connection, for Vaillant boilers from the VM, VMI, VMW, VUI, VUW, VKC, and AquaPlus series, among the indicated compatible models. It releases pressure from the heating circuit when the set limit is exceeded, protecting the heat exchanger from overpressure. It should be replaced when it continuously drips or fails to activate upon reaching the set pressure.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 190732
Safety valve with reference 190732. Nine confirmed compatibilities: VMI 280-7 and VMI 282-7.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMI 280-7 | Acquablock (VMI) | Contrasted |
| Vaillant VMI 282-7 | Acquablock (VMI) | Contrasted |
| Vaillant VMI 280-7 R3 | Acquablock (VMI) | Contrasted |
| Vaillant VMI 282-7 R2 | Acquablock (VMI) | Contrasted |
| Vaillant VMW 275/3-7 | Turbotec / Atmotec (VMW) | Contrasted |
| Vaillant VMW 242/2-3 | Turbotec / Atmotec (VMW) | Contrasted |
| Vaillant VMW 242 | Turbotec / Atmotec (VMW) | Contrasted |
| Vaillant VMW 280 | VM / VMW (Atmoblock / Turboblock) | Contrasted |
| Vaillant VMW 282 | VM / VMW (Atmoblock / Turboblock) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 190732 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 190732. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 190732 resolves.
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve is continuously leaking through the discharge pipe.
Cause: The seat doesn't close properly, usually due to lime or dirt lodged in the mechanism.
Measure the cold pressure of the circuit; if it is already above normal at rest, check the filling and the expansion vessel first.
- 02
The valve does not activate when the circuit reaches high pressure.
Cause: The mechanism may be seized due to lack of use, leaving the heat exchanger without real protection against overpressure.
Activate the test lever with the boiler cold to check if it bleeds water before replacing it.
- 03
The valve activates either well before the pressure reaches high levels or much later than expected.
Cause: If the trip does not match what the pressure gauge indicates, the internal calibration mechanism has lost precision.
Compare the pressure indicated by the manometer at the moment of the trip in several tests before concluding that it has lost calibration.
- 04
The circuit loses pressure and no visible leak appears in radiators or pipes.
Cause: The water is being bled through the discharge pipe of the valve, without leaving any visible trace.
Check the outlet of the discharge pipe for any signs of scale or recent moisture before inspecting other areas of the circuit.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Vaillant safety valve 190732
- Catalogue reference
- 190732
- Brand
- Vaillant
- Type of part
- Safety valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Connection
- DN15
- Setpoint
- 3 bar
- Approval code
- TÜV·SV·13-1089-H-60