Baxi Combi 105HE 3-Way Valve - Ref. 248061
In the Baxi Combi 105HE boilers, the 3-way valve is essential for directing water between the heating circuit and the domestic hot water circuit. If this valve fails, you may notice that you have hot water but no heating, or vice versa, or even that both circuits are mixing. This model is compatible with several boilers from the Cointra range, such as the Edyco ED 21 EI and the Supra SP 27 EI, among others. It is advisable to replace it when you experience these heating or hot water issues.
VAT included
Consult via WhatsAppCointra boilers compatible with reference 9158454
Three-way valve with reference 9158454. Six confirmed compatibilities: Edyco ED 21 EI and Edyco ED 21 I.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Cointra Edyco ED 21 EI | Cointra | Contrasted |
| Cointra Edyco ED 21 I | Cointra | Contrasted |
| Cointra Supra SP 21 EI | Cointra | Contrasted |
| Cointra Supra SP 21 I | Cointra | Contrasted |
| Cointra Supra SP 24 I | Cointra | Contrasted |
| Cointra Supra SP 27 EI | Cointra | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 9158454 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 9158454. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 9158454 resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The domestic hot water comes out lukewarm and never really gets hot, even though the burner ignites.
Cause: The shutter does not fully move to the DHW side, causing some of the heat to be lost to the heating circuit.
Temporarily raise the domestic hot water thermostat to the maximum to rule out a low setting before checking the gas valve.
- 02
The radiators are hot when there shouldn't be any heating demand, with the room thermostat turned off.
Cause: If the stem does not return to its resting position, it continues to allow hot water to flow to the radiators even when there is no demand.
Check that the room thermostat and the programmer are actually turned off before assuming that the gas valve has remained open.
- 03
When switching from heating to domestic hot water, a motor can be heard forcing for several seconds before noticing the change.
Cause: The valve motor takes longer than usual to move the shutter due to mechanical resistance, typically caused by accumulated scale.
Count the seconds it takes to switch; if it clearly exceeds the usual few seconds, there is more resistance than normal in the mechanism.
- 04
The boiler gradually loses pressure and needs to be refilled every so often, with no visible leak in any radiator.
Cause: A damaged internal gasket in the 3-way valve can allow water to pass between circuits or to the outside without leaving an obvious puddle.
First, check the usual points of leakage (bleed valves, expansion vessel, safety group) before disassembling the gas valve to inspect it.
- 05
There is no domestic hot water at all, although the heating is working normally.
Cause: If the shutter gets stuck in the heating position, all the flow goes to the radiators and nothing reaches the domestic hot water circuit.
First, check the flow meter or the domestic hot water flow sensor before replacing the gas valve, because a fault there produces the same symptom.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Cointra 9158454 three-way valve.
- Catalogue reference
- 9158454
- Brand
- Cointra
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Cointra Edyco ED 21 I Manual (PDF)Document © Cointra, provided as a technical reference.