Vaillant Thermomanometer VC / VCM / VMW Ref. 101558

Vaillant Thermomanometer VC / VCM / VMW Ref. 101558

20 €VAT includedIn stock · 1 unit

Analog thermometer-manometer mounted on the boiler panel, with a dial indicating water temperature (approximately 0-120 °C) and circuit pressure (0-4 bar). It allows for a quick check to see if the system has sufficient pressure to operate. It should be checked or replaced when the needle does not indicate correctly, the glass is broken, or there is a leak at the circuit connection.

Spare parts related to Vaillant VC / VCM (Turbo/ThermoCompact)

Compatibility

Vaillant boilers compatible with reference 101558

Manometer with reference 101558. 13 confirmed compatibilities with two independent sources: VC 242 E and VCM 242 E. Verify the reference printed on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Vaillant VC 242 EVC / VCM (Turbo/ThermoCompact)Confirmed · 2 sources
Vaillant VCM 242 EVC / VCM (Turbo/ThermoCompact)Confirmed · 2 sources
Vaillant VCM 182 EVC / VCM (Turbo/ThermoCompact)Confirmed · 2 sources
Vaillant VCM 282 EVC / VCM (Turbo/ThermoCompact)Confirmed · 2 sources
Vaillant VMW 242 EVMW (Turbo/Atmo)Confirmed · 2 sources
Vaillant VMW 282 EVMW (Turbo/Atmo)Confirmed · 2 sources
Vaillant VMW 240VMW (Turbo/Atmo)Confirmed · 2 sources
Vaillant VMW 280VMW (Turbo/Atmo)Confirmed · 2 sources
Vaillant VM 180VMConfirmed · 2 sources
Vaillant VM 280VMConfirmed · 2 sources
Vaillant VM 240VMConfirmed · 2 sources
Vaillant VM 282 EVMConfirmed · 2 sources
Vaillant VU 242 EVU (TurboMax/atmoMax)Confirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 101558 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the pressure gauge you have installed: it should indicate 101558.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by pressure gauge 101558

The pressure gauge shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

The pressure needle always shows the same reading, whether water is added or removed from the circuit.

Cause: The mechanism of the pressure gauge gets internally stuck and stops moving with the actual pressure changes.

Fill the system a bit with the filling key and check if the needle reacts before replacing the part.

Water is leaking on the panel, right in the area where the thermometer-manometer is mounted.

Cause: The connection of the thermometer-manometer to the circuit loses its seal with use, and water leaks through there.

Locate the exact point of the leak with dry paper before purchasing; it may be coming from a nearby valve and not from the pressure gauge itself.

The water temperature is not clearly visible on the dial, although the pressure can be read normally.

Cause: The temperature indicator and the pressure indicator share a dial but are independent mechanisms, and one can fail without the other.

Note if only the temperature needle fails or if the pressure needle does as well; this helps confirm if the entire part is needed.

The glass of the dial is broken or very scratched, and the reading is no longer distinguishable.

Cause: It is the most exposed part of the component, and a bump during an inspection or cleaning is usually the reason.

Check that the break is only in the glass and that the needle continues to move as the pressure changes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 101558 pressure gauge datasheet

OEM reference
101558
Brand
Vaillant
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Temperature range (dial)
0-120 °C
label
Pressure range (gauge)
0-4 bar
label
Before purchasing
  • The manufacturer of this part is not listed on the label or in external sources: the photographed unit does not have legible markings.
  • The manufacturer's code or reference for the component is not known. The reference shown on the store's product sheet today cannot be considered valid: it is not confirmed by the label or any source.
  • Before ordering, visually check the diameter of the gauge and the type of connection of your current thermometer-manometer, as there is no manufacturer data to verify it otherwise.
  • The list of compatible boilers is long and includes very similar numbering variants (for example, VM 180 X versus VM 180/1 X); check the exact model, including the version slash, before ordering.
Frequently Asked Questions

Frequently Asked Questions about Pressure Gauge 101558

Is this thermomanometer suitable for an Atmoblock VM 240 X boiler?
Yes, it is suitable for the Atmoblock VM 240 X, as well as for the rest of the Atmoblock VM/VMW range and for the Thermocompact VU 182 E.
When should the thermomanometer of the Atmoblock VMW 242 E be replaced?
When the needle does not indicate correctly, the glass is broken, or a leak appears in the connection to the circuit.
Who manufactures this thermometer-manometer for the Thermocompact VU 142/1 E?
It is not recorded; there is no legible marking on the piece nor any external references to confirm it.
What pressure and temperature range does this thermomanometer indicate on an Atmoblock VM 280 X?
From 0 to 4 bar of pressure and from 0 to 120°C of temperature approximately, according to the gauge.
Is this thermomanometer suitable for any Atmoblock, regardless of the exact version?
No; only for the exact models listed, including the version (e.g., VMW 242 E BALKON or VU 182/1 E), so it's advisable to check yours before ordering.
Does this thermometer-manometer have a manufacturer reference to find an equivalent for the Thermocompact VU 182/1 E?
No manufacturer code could be read on the part.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model