Boiler Extractor VCM 182/1 E / VMW 182 E Ref. 0020073797

Boiler Extractor VCM 182/1 E / VMW 182 E Ref. 0020073797

The extractor of the VCM 182/1 E / VMW 182 E boiler is a flue fan responsible for expelling combustion gases and creating the necessary draft for the boiler to start. When this part fails, the user will notice that the boiler does not ignite or locks out due to a flue gas evacuation fault, and fault codes F.32, F.37, or F.38 may appear. This extractor is compatible with several models, including VCM 182 E, VMW 182 E, and VM 242 E. A technician must confirm through diagnosis whether it needs to be replaced when a fault in its operation occurs, affecting the boiler's performance.

Type of part
Extractor fans
Catalogue reference
0020073797
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Vaillant boilers compatible with reference 0020073797

Extractor with reference 0020073797. 15 verified compatibilities: VM 242 E and VMW 182 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VM 242 EATMOBLOCK (E)Contrasted
Vaillant VMW 182 EATMOBLOCK (E)Contrasted
Vaillant VMW 242 EATMOBLOCK (E)Contrasted
Vaillant VMW 282 EATMOBLOCK (E)Contrasted
Vaillant VM 242/1 ETURBOBLOCK (/1 E)Contrasted
Vaillant VM 282/1 ETURBOBLOCK (/1 E)Contrasted
Vaillant VMW 182/1 ETURBOBLOCK (/1 E)Contrasted
Vaillant VMW 242/1 ETURBOBLOCK (/1 E)Contrasted
Vaillant VMW 282/1 ETURBOBLOCK (/1 E)Contrasted
Vaillant VCM 182 EVCMContrasted
Vaillant VCM 182/1 EVCMContrasted
Vaillant VCM 242/1 EVCMContrasted
Vaillant VCM 282/1 EVCMContrasted
Vaillant VC 242 EVCContrasted
Vaillant VC 242/1 EVCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020073797 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020073797. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the extractor 0020073797

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler won't start and gets locked immediately upon trying.

    Cause: If the extractor does not reach the required air flow, the pressure switch does not close and the control board does not allow the gas to flow.

    Before replacing the extractor, check that the exhaust duct is not obstructed from the outside (snow, leaves, insects).

  • 02

    An abnormal noise or vibration is noticeable in the fan while it is operating.

    Cause: The wear of the impeller or bearings causes friction or imbalance over time.

    With the boiler unplugged, manually turn the impeller to check for any friction, play, or objects stuck inside.

  • 03

    The fan takes a long time to start or rotates with difficulty at the beginning of the ignition cycle.

    Cause: After a period of inactivity, the shaft may seize slightly due to dryness or internal dirt.

    Check if the impeller starts on its own after giving it a small manual push; if so, it points to seizing rather than a burnt-out motor.

  • 04

    The boiler starts up fine on some days and on others it locks out for no apparent reason.

    Cause: An extractor that intermittently loses revolutions causes irregular evacuation faults.

    Note if the fault coincides with strong winds or bad weather, indicating that the problem may be in the duct and not in the extractor.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.32Fan fault: defective or not connected fan.The VCM 182 extractor does not start or does not deliver Hall rpm signal to the PCB (motor blocked, loose connector/wiring, or damaged winding). Check power supply voltage and Hall signal at the fan connector and ensure the impeller spins freely.
F.37The fan speed during operation is too high or too low.The VCM 182 extractor does not maintain speed within tolerance (seized bearings, motor defects, or Hall sensor issues). Check rpm in diagnostics, fan condition, and wiring; if the issue persists, measure Hall signal and motor consumption.
F.38Fan short circuit.Electrical short in the VCM 182 extractor motor or its wiring harness causes detection of 'ventilatorkurzschluss'. Check motor insulation, continuity/derivations of the harness, and consumption when powered.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant extractor datasheet 0020073797

Catalogue reference
0020073797
Uniclima internal SKU
ECTVCMES182
Brand
Vaillant
Type of part
Extractor fans
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Reference code
0020073797
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the extractor 0020073797

Is this extractor compatible with a VCM 182/1 E boiler?
Yes, it is on the list of compatible models (VCM range).
Is this extractor suitable for a VMW 282/1 E boiler?
Yes, the VMW 282/1 E is listed among the models compatible with reference 0020073797.
When should this fan be replaced in a VMW 182 E?
The technical diagnosis must confirm that it is necessary to replace it, even when the boiler does not start due to a flue fault or the fan makes noise.
How many models are compatible with this extractor?
There are a total of 15 compatible models in the ATMOBLOCK, TURBOBLOCK, and VCM ranges.
What fault codes are documented for this extractor?
The documented fault codes are F.32, F.37, and F.38.
What is the reference for this extractor?
ECTVCMES182 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Boiler Extractor VCM 182/1 E / VMW 182 E Ref. 0020073797