Ebm-papst Extractor Code 55730.33010 For Micraplus Condens 25-A, Semia Condens 25-A, SemiaFast Condens 25-A, and Thelia Condens 25-A
Extractor (fan) manufactured by ebm-papst (Made in Germany), model NRV77/3300-2212-032411-V32.0, article code 55730.33010. It is responsible for evacuating the combustion gases from the boiler. It operates at 23V DC and 60W (I.Cl.H), according to the label. It is replaced when the fan does not start, makes noise or vibrates, or the boiler locks due to a flue gas evacuation fault.
VAT included
Consult via WhatsAppHermann boilers compatible with reference 0020195507
Extractor with reference 0020195507. Four confirmed compatibilities: Micraplus Condens 25-A and Semia Condens 25-A.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann Micraplus Condens 25-A | Hermann Micraplus Condens | Contrasted |
| Hermann Semia Condens 25-A | Saunier Duval Semia Condens | Contrasted |
| Hermann Semia Condens F25-A/1 | Saunier Duval Semia Condens | Contrasted |
| Hermann Thelia Condens 25-A | Saunier Duval Thelia Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0020195507 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020195507. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor 0020195507 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, a beeping or buzzing sound is heard but it does not start and gets locked with a flue or ventilation fault.
Cause: The extractor does not reach the necessary speed for the pressure switch to confirm sufficient draft, and the control board interrupts the ignition attempt.
Listen to see if the extractor spins when you request ignition: if it sounds strained or doesn't start, check that the flue gas outlet is not blocked.
- 02
A buzzing, squeaking, or loud vibration can be heard in the area of the extractor, even when the boiler is operating normally.
Cause: It is typical of a worn motor bearing or an unbalanced turbine due to dirt accumulation on the blades.
With the boiler off, check if the turbine has dust or grease stuck to the blades; sometimes cleaning it is enough to reduce the noise.
- 03
The boiler locks out with a fault code related to flue gas or air, and not always at the same time.
Cause: The extractor motor intermittently loses revolutions and does not always reach the minimum flow required for the safety of the boiler.
Note if the blockage coincides with strong winds or poor outlet from the external duct: first rule out a flue problem before checking the fan.
- 04
The extractor does not start at all, although the boiler tries several times in a row.
Cause: It may be due to the motor not receiving power or because the winding is damaged and no longer responds to the start command.
Check that the extractor connector is properly fitted and free of moisture before confirming the fault.
Fault codes Hermann that this part solves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.32 | Frost protection function of the fan active: fan revolutions exceed tolerance values. | The extractor motor/fan fails (blockage, bearings, or Hall signal out of range) and the PCB detects abnormal speed; check supply voltage, connector, and ensure the fan rotates freely, and check Hall signal/rpm reading in diagnostics, as well as rule out obstructions in intake/exhaust. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Hermann extractor datasheet 0020195507
- Catalogue reference
- 0020195507
- Brand
- Hermann
- Type of part
- Extractor fans
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- ebm-papst (Made in Germany)
- Fan code
- NRV77/3300-2212-032411-V32.0
- Voltage
- 23V DC
- Power
- 60W (I.Cl.H)
- ebm-papst article code
- 55730.33010
- Manufacturing batch code
- FA1500008704 OF (L) 33/17